Norgren Collateral

z7411CT - Distributor Process catalog

Issue link: https://onenorgren.uberflip.com/i/552086

Contents of this Issue

Navigation

Page 53 of 100

1 53 P A P A For further information www.norgren.com/us VALVES Symbol Model Orifice (mm) Port size *1 Kv-value (m 3 /h) Operating pressure (bar) 8254000.9150.00000 8 G1/4 1.9 0…10 8254100.9150.00000 10 G3/8 3 0…10 8254200.9150.00000 12 G1/2 3.4 0…10 8254300.9150.00000 20 G3/4 5.8 0…10 8254400.9150.00000 25 G1 8 0…10 Symbol Model Orifice (mm) Port size *1 Kv-value (m 3 /h) Operating pressure (bar) 8259000.9150.00000 8 G1/4 1.9 0…10 8259100.9150.00000 10 G3/8 3 0…10 8259200.9150.00000 12 G1/2 3.4 0…10 8259300.9150.00000 20 G3/4 5.8 0…10 8259400.9150.00000 25 G1 8 0…10 Models - Brass Models - Stainless steel Medium: Neutral gases and liquids (82540) Slightly aggressive, gases and liquids (82590) Flow direction: Fixed Operating pressure: 0 … 10 bar (0 ... 145 psi) Temperatur: Fluid –10°C … +90°C (14 ... +194°F) max. Ambient –10°C … +50°C (14 ... +122°F) max. Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F). Materials: Body: Brass (82540) Stainless steel (82590) Seat Seal: NBR-K Internal Parts: Stainless steel, PVDF, Brass For contaminated fluids installations of an upstream filter is recommended. Technical features Solenoid interchangeable without tools (Click-on ® ) Other functions and operating voltages available on request Solenoid operators Design DIN VDE 0580 Voltage range ±10% Duty cycle 100% ED Protection EN 60529 IP65 Connector Form A to DIN EN 175301-803 (included) Electrical details for all solenoid systems Voltage and Frequency Solenoid 9151/9154 *1 Code Voltage Code Frequency Voltage Frequency Power consumption Inrush- Holding- power power 024 00 24 VDC - 18 W 18 W 024 50 24 VAC 50 Hz 20 VA 20 VA 110 50 110 VAC 50 Hz 20 VA 20 VA 120 60 120 VAC 60 Hz 20 VA 20 VA 230 50 230 VAC 50 Hz 20 VA 20 VA Voltage and Frequency Solenoid 9301/9304 *1 024 00 24 VDC - 18 W 18 W 024 50 24 VAC 50 Hz 20 VA 20 VA 110 50 110 VAC 50 Hz 20 VA 20 VA 120 60 120 VAC 60 Hz 20 VA 20 VA 230 50 230 VAC 50 Hz 20 VA 20 VA Voltage and Frequency Solenoid 9401/9404 *1 024 00 24 VDC - 38 W 38 W 024 49 24 VAC 40 ... 60 Hz 42 VA 42 VA 110 49 110 VAC 40 ... 60 Hz 42 VA 42 VA 120 49 120 VAC 40 ... 60 Hz 42 VA 42 VA 230 49 230 VAC 40 ... 60 Hz 42 VA 42 VA ATEX Category Protection Solenoid Standard voltage II2GD EEx me II T3 T 140°C 9356 24 VDC, 110 VAC, 230 VAC II3GD EEx nA II T4 T 135°C 9326 24 VDC, 110 VAC, 230 VAC II3GD EEx nA II T4 T 135°C 8426 24 VDC, 110 VAC, 230 VAC II2GD EEx me II T3 T 140°C 8441 24 VDC, 110 VAC, 230 VAC II3GD EEx nA II T4 T 135°C 9176 24 VDC, 110 VAC, 230 VAC II2GD EEx me II T3 T 140°C 9191 24 VDC, 110 VAC, 230 VAC II3GD EEx nA II T4 T 135°C 9426 24 VDC, 110 VAC, 230 VAC Additional solenoid systems *1 Voltage Buschjost 82540 & 82590 Solenoid actuated diaphragm valve with forced lifting 2/2 N/C, G1/4…G1 According to DIN VDE 0580 at a solenoid temperature of +20°C. At elevated temperatures, the power of the solenoid coil could be reduced by up to 30%. Attention! The conditions imposed on the Ex approvals lead to reduction of the permissible standard temperature ranges in the cases of explosion protected solenoids. *1 NPT versions may be available upon request. Contact technical support. *1 NPT versions may be available upon request. Contact technical support.

Articles in this issue

Links on this page

Archives of this issue

view archives of Norgren Collateral - z7411CT - Distributor Process catalog