Issue link: https://onenorgren.uberflip.com/i/552086
54 1 P A P A For further information www.norgren.com/us VALVES Symbol Port size Orifice (mm) Valve length (mm) Kv-value *1 (m 3 /h) Operating pressure (bar) Model G3/4 20 95 18 0.4 ... 8 8296300.8171.xxxxx 3/4 NPT 20 95 18 0.4 ... 8 8297300.8171.xxxxx G1 25 95 22 0.4 ... 8 8296400.8171.xxxxx 1 NPT 25 95 22 0.4 ... 8 8297400.8171.xxxxx G1 1/2 40 135 59 0.4 ... 8 8296600.8171.xxxxx 1 1/2 NPT 40 135 59 0.4 ... 8 8297600.8171.xxxxx G2 50 169 80 0.4 ... 8 8296700.8171.xxxxx 2 NPT 50 169 80 0.4 ... 8 8297700.8171.xxxxx G2 1/2 65 169 93 0.4 ... 8 8296800.8171.xxxxx 2 1/2 NPT 65 169 93 0.4 ... 8 8297800.8171.xxxxx G3 80 239,5 172 0.4 ... 7 8296900.8171.xxxxx Medium: Compressed air Flow direction: Fixed Operating pressure: 0,4 ... 7/8 bar (5,8 ... 101/116 psi) Fluid temperature: -40...+85°C (-40 ... +185°F) Ambient temperature: –20 ... +85°C (-4 ... +185°F) Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F). Materials: Body: Aluminum Seat Seal: TPE Internal Parts: TPU Technical features Solenoid interchangeable without tools (Twist-on) Easy to maintain Technical features - Standard models xxxxx Please insert voltage and frequency codes *1 Cv-value (US) ≈ kv value x 1,2 Solenoid operators Design DIN VDE 0580 Voltage range ±10% Duty cycle 100% ED Protection EN 60529 IP65 Connector Form A to DIN EN 175301-803 (included) Electrical details for all solenoid systems Voltage and Frequency Solenoid 8171 *1 Code Voltage Code Frequency Voltage Frequency Power consumption Inrush- Holding- power power 024 00 24 VDC - 12 W 12 W 024 50 24 VAC 50 Hz 23 VA 16 VA 110 50 110 VAC 50 Hz 23 VA 16 VA 120 60 120 VAC 60 Hz 23 VA 16 VA 230 50 230 VAC 50 Hz 23 VA 16 VA ATEX Category Protection Solenoid Standard voltage II3GD EEx nA II T4 T 135°C 8176 24 VDC, 110 VAC, 230 VAC II2GD EEx me II T4 T 140°C 8186 24 VDC, 110 VAC, 230 VAC Additional solenoid systems *1 Voltage Option Solenoid Standard voltage Solenoid version for low temperature = 40°C 9151 24 VDC, 110 VAC, 230 VAC Pulse Solenoid 8821 24 VDC, 110 VAC, 230 VAC Solenoid version for low temperature = 40°C 8001 24 VDC, 110 VAC, 230 VAC Additional solenoid systems According to DIN VDE 0580 at a solenoid temperature of +20°C. At elevated temperatures, the power of the solenoid coil could be reduced by up to 30%. Attention! The conditions imposed on the Ex approvals lead to reduction of the permissible standard temperature ranges in the cases of explosion protected solenoids. 82960, 82970 2/2-way diaphragm valves G3/4 ... 3, 3/4 ... 2 1/2 NPT