Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. © 2015 Norgren, Inc. Simplified Valve Circuit Guide 11 Sequence Circuit, Cylinders Extend in Succession, Three Valves. (Spool Valves Shown) The sequence valve can be adjusted to allow the second cylinder to extend after cylinder number 1 has extended fully and the pressure has built up. Cylinder number 2 pressure is independent of cylinder number 1 pressure, the force generated by cylinder number 2 is not dependent on cylinder number 1. Note: A bleed must be provided as shown to exhaust pilot air. Time Based, Cylinders Extend in Succession. (Poppet Valves Shown) Cylinder number 2 extends only after a time delay, which starts when cylinder number 1 is extended. CYLINDER 1 1 14 12 3 5 1 3 2 1 14 12 3 5 CYLINDER 2 BLEED SEQUENCE VALVE 4 2 4 2 CYLINDER NO. 2 IN EX CYL. 1 CYL. 2 MANUAL VALVE CYLINDER NO.1 IN EX CYL. 1 CYL. 2 TIME DELAY This circuit is not suitable for use with Poppet valves because of crossover during shifting.