Norgren Collateral

z7420BR - Valve Circuit Guide

Issue link: https://onenorgren.uberflip.com/i/508614

Contents of this Issue

Navigation

Page 11 of 26

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. © 2015 Norgren, Inc. Simplified Valve Circuit Guide 10 Cylinder Extends, Retracts Automatically. (Spool Valve Shown) Operation of the manual valve causes the cylinder to extend, actuating the limit valve which resets the manual valve retracting the cylinder. Sequence Circuit, Cylinders Extend in Suc- cession, Two Valves. (Spool and Poppet Valves Shown) Cylinder number 1 extends when the manual valve is actuated. When the pressure builds up to overcome the set pressure of the sequence valve (relief valve), cylinder number 2 extends. 1 2 14 CYLINDER 4 12 3 5 MANUAL VALVE 2 3 1 LIMIT VALVE EX CYL. 1 CYL. 2 SEQUENCE VALVE CYLINDER NO. 2 CYLINDER NO.1 1 3 2 SPOOL VALVE POPPET VALVE IN

Articles in this issue

Archives of this issue

view archives of Norgren Collateral - z7420BR - Valve Circuit Guide