Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document. © 2015 Norgren, Inc.
Simplified Valve Circuit Guide
12
Event Based, Cylinders Extend in Succession.
(Poppet Valves Shown)
Cylinder number 2 extends only after cylinder number 1 has
reached a predetermined stroke (limit valve). Cylinders will retract
almost simultaneously when the manual valve
is released.
Event Based, Cylinders Extend, Retract
Automatically.
(Spool Valves Shown)
This circuit, when manually initiated, will cause the two cylinders to
extend in sequence, then retract automatically. The manual valve
will be returned to its original position in the process.
CYLINDER 1
LIMIT VALVE
CYL. 1
CYL. 2
MANUAL
VALVE
IN
EX
IN
EX
CYLINDER 2
CYL. 1
CYL. 2
1
2
14
CYLINDER NO. 1
4
12
3 5
MANUAL
VALVE
1
LIMIT VALVE
1
5
3
14
12
2
4
2
3
10
12
CYLINDER NO.2
LIMIT VALVE