Pneumatic & Fluid Control Catalog - z7424CT

09 - Lintra Plus Rodless Cylinders

Issue link: https://onenorgren.uberflip.com/i/555878

Contents of this Issue

Navigation

Page 3 of 25

ACTUATORS 1 ACT-131 For further information www.norgren.com 18 (8) 2204 (1000) lb. (kg) inches /s (m / s) ø 16 ø 20 ø 25 ø 32 ø 40 ø 50 ø 63 ø 80 1763 (800) 1300 (600) 882 (400) 441 (200) 176 (80) 132 (60) 88 (40) 44 (20) 22 (10) 13 (6) 8.8 (4) 4.4 (2) 2.2 (1) 16" (0.4) 31" (0.8) 47" (1.2) 63" (1.6) 79" (2.0) V Cushioning Performance The dynamic energy of a LINTRA ® cylinder is caused by direct or partial external loads which must be absorbed by pneumatic cushioning. The cushioning ability depends to a large extent on the pneumatic circuit (e. g. counter pressure, pre-exhaust). The values given in the diagram were tested with an operation pressure of 87 psi (6 bar) using a 5/2 control valve. When installed horizontally, depending upon the speed, dynamic energy can be absorbed by the cylinder. Whenever the values given in the diagram are exceeded, the transported mass must be cushioned by additional shock absorbers. These have to be located at the center of gravity of the mass. inches (mm) 19.7' (6000) 16.4' (5000) 13' (4000) 9.8' (3000) 6.5' (2000) 3.2' (1000) 0 2 0.04" (1) 0.004" (0.1) 0.02" (0.4) ft. (mm) f 0.08" (2) 0.04 (0.9) Cylinder deflection Support length Deflection due to cylinder weight Example: Cylinder Ø 32 mm, stroke length 11' (3500 mm), external load 45 lbf. (200 N) and a deflection about 0.04 (1 mm). Maximum distance between supports = 6' (1830 mm) (see diagrams). Therefore an additional support is required. 72" (1830) inches (mm) f1= 0.04" (1 mm) 2248 (10000) 1124 (5000) 224 (1000) 112 (500) 22.5 (100) 2.25 (10) 0.22 (1) 39" (1000) 0 6.6' (2000) 9.8' (3000) 13' (4000) 16.4' (5000) 19.6' (6000) F ibf (N) ø80 ø63 ø50 ø40 ø32 ø25 ø20 ø16 Deflection due to external forces Support length Example: Cylinder Ø 40 mm. external force 40 lbf (180 N), distance between supports 10' (3000 mm) Required: total deflection 1. Deflection due to external force (f1) see Diagram 1 (1mm /100 N) · 40 lbf (180 N) 2. Deflection due to cylinder weight diagram 2 Total deflection: Max. permitted deflection (f1 + f2) A deflection of more than 0.12" (3 mm) is not permitted. 0.07"(1.8 mm) + 0.04"(0.9 mm) 0.2" (2.7 mm) < 0.04"(1 mm) 39"(1000 mm) Stroke LINTRA ® PLUS Rodless cylinders 146000, 146100, 146200 Internal, external and precision roller guided Double acting

Articles in this issue

Links on this page

Archives of this issue

view archives of Pneumatic & Fluid Control Catalog - z7424CT - 09 - Lintra Plus Rodless Cylinders