SWITCHES AND SENSORS For further information www.norgren.com 3 SAS-27 Specifications: Stem and 316 SS and Mounting Material Brass up to 72" Length Switches SPST, 10VA, 50VA or 100VA SPDT, Optional Float Stops Brass Units - Beryllium Copper Grip rings SS Units - ARMCO PH 15-7 MO 316 SS Collar Optional Leads 22 AWG, 24" long A = minimum distance to highest level B = minimum distance between levels using two floats C = distance from lowest level to end of unit A C B Float Number A Dim. B Dim. C Dim. 0127-001 1-1/2" 3" 2" 0114-001 1-1/2" 3" 2" 0489-001 1-1/2" 3" 2" 2305-001 1-1/2" 3" 2" Mounting Styles SELECTION CHOICES TYPE 1 TYPE 2 TYPE 3 TYPE 4 TYPE 5 TYPE 6 Unit Configuration Mounting 1/2" NPT 1-1/4" NPT 2" NPT 3" 150# CS Flange 1/2" Tubing 1-1/2 NPT Max. Length 72" 72" 72" 72" 72" 72" 0127-001 316 SS Float 0114-001 Buna N (closed cell) Float 0489-001 Buna N (closed cell) Float 2305-001 PVC Float FLOAT CHOICES Maximum Pressure 750 PSI (51.7 bar) 150 PSI (10.4 bar) 150 PSI (10.4 bar) 15 PSI (1.03 bar) Operating Temperature -40°F to 300°F (-40°C to 149°C) (Oil) -40°F to 225°F (-40°C to 107°C) (Water) -40°F to 180°F (-40°C to 82°C) (Oil) -40°F to 225°F (-40°C to 107°C) (Water) -40°F to 180°F (-40°C to 82°C) -40°F to 150°F (-40°C to 66°C) Recommended Min. Liquid SP GR .73 .58 .55 .55 2.00 (51) 2.15 (55) 1.75 (44) 1.19 (30) 1.88 (48) 1.88 (48) 1.88 (48) 1.88 (48) KIP Multi-Point Multi-Point Design Considerations