VALVES
2
VAL-297
For further information www.norgren.com
Series 3 - 3/2 NC Cv and MOPD Values
Low Watt Specifications
Orifice
Size
MOPD
(psi)
Cv Value
Body
Cv Value
Endstop
Part
Numbering
Low Watt
Cv Value
Body
Cv Value
Endstop
2.5 Watt
C
3.0 Watt
D
5/64 100 0.125 0.145 3***33 5/64 75 – 13
3/32 75 0.165 0.145 3***34 3/32 50 – –
1/8 45 0.240 0.145 3***35 1/8 25 – –
5/32 20 0.290 0.145 3***36 5/32 15 – –
3/16 10 0.345 0.145 3***37 3/16 10 – –
1/4 5 0.415 0.145 3***38 1/4 5 – –
Series 3 - 3/2 MP Cv and MOPD Values
Orifice Size MOPD Cv Value
Body
Cv Value
Endstop
Part
Numbering
5/64 75 0.125 0.145 3***63
3/32 50 0.165 0.145 3***64
1/8 25 0.240 0.145 3***65
5/32 15 0.290 0.145 3***66
3/16 10 .0345 0.145 3***67
1/4 5 0.415 0.145 3***68
U 3 4 3 1 1 1 - 0 1 5 1 - 12 VDC
Series 3 - 3/2 Direct Acting Valves
Orifice Ø5/64" to Ø1/4"
Series 3 - 3/2 NO Cv and MOPD Values
Orifice
Size
MOPD Cv-Value
Body
Cv-Value
Endstop
Part
Numbering
5/64 75 0.125 0.145 3***53
3/32 50 0.165 0.145 3***54
1/8 25 0.240 0.145 3***55
5/32 15 0.290 0.145 3***56
3/16 10 0.345 0.145 3***57
1/4 5 0.415 0.145 3***58
Series 3
Prefix Substitute
UL recognized U
Oxygen clean Y
Low watt* - 2.5 C
Low watt* - 3.0 D
Port Configuration Substitute
1/4" NPTF 5
Manifold Mount 6
Housing Substitute
Grommet 1
1/2" NPT Conduit 2
Yoke 3
Grommet w/ bracket 7
Slotted 9
Body material Substitute
Stainless Steel 0
Brass 1
Function Substitute
3WNC
3
3WNO
5
3WMP
6
Voltage
12 VDC
24 VDC
24 - 60 VAC
120 - 60 VAC
240 - 60 VAC
Coil Options Substitute
Dry taped with 24" Flying Leads 01*
Molded with 1/4" top spade 51*
Free standing molded 24" Flying Leads 61*
Seal Options Substitute
Buna 01
Fluorocarbon 02
Polyurethane (2WNC Only) 06
Ethylene Propylene (EPR) 13
Orifice Substitute
5/64
3
3/32
4
1/8
5
5/32
6
3/16 7
1/4 8
*For class H coils replace second digit with 3.
Example: 43 = Class H molded with Flying Leads