Pneumatic & Fluid Control Catalog - z7424CT

07 - IMI KIP Valves & Manifolds

Issue link: https://onenorgren.uberflip.com/i/555071

Contents of this Issue

Navigation

Page 15 of 50

2 VALVES VAL-292 For further information www.norgren.com Series 2 - 3/2 MP Cv and MOPD Values Low Watt Specifications (MOPD (psi)) Orifice Size MOPD (psi) Cv Value Body Cv Value Endstop Part Numbering Low Watt Cv Value Body Cv Value Endstop 2.5 Watt C 3.0 Watt D 1/32 175 0.035 0.025 2***60 0.030 0.025 40 105 3/64 125 0.050 0.065 2***61 0.050 0.060 35 65 1/16 100 0.085 0.115 2***62 0.085 0.105 10 15 5/64 75 0.125 0.140 2***63 0.120 0.125 - 13 3/32 50 0.165 0.140 2***64 0.150 0.125 - - 1/8 25 0.240 0.140 2***65 0.225 0.125 - - 5/32 15 0.285 0.140 2***66 0.270 0.125 - - For low watt valves, please use the prefix C for 2.5 Watt; and D for 3.0 Watt U 2 4 3 1 3 1 - 0 1 5 1 - 12 VDC Series 2 - 3/2 Direct Acting Valves Orifice Ø1/32" to Ø5/32" Series 2 - 3/2 NC Cv and MOPD Values Orifice Size MOPD Cv-Valve Body Cv-Valve Endstop Part Numbering 1/32 250 0.035 0.025 2***40 3/64 175 0.050 0.065 2***41 1/16 125 0.085 0.115 2***42 5/64 100 0.125 0.140 2***43 3/32 75 0.165 0.140 2***44 1/8 45 0.240 0.140 2***45 5/32 20 0.285 0.140 2***46 Series 2 - 3/2 NO Cv and MOPD Values Orifice Size MOPD Cv-Valve Body Cv-Valve Endstop Part Numbering 1/32 200 0.035 0.025 2***50 3/64 150 0.050 0.065 2***51 1/16 125 0.085 0.115 2***52 5/64 100 0.125 0.140 2***53 3/32 75 0.165 0.140 2***54 1/8 60 0.240 0.140 2***55 5/32 25 0.285 0.140 2***56 NOTE: Valve dimensions and housing options shown at end of Series 2 Section Series 2 - 3/2 Direct acting valves Prefix Substitute UL recognized U Oxygen clean Y Low watt* - 2.5 C Low watt* - 3.0 D Port Configuration Substitute 1/8" NPTF 4 Manifold Mount 6 Housing Substitute Grommet 1 ½" NPT Conduit 2 Yoke 3 Grommet w/ bracket 7 Body material Substitute Stainless Steel 0 Brass 1 Function Substitute 3WNC 3 3WNO 5 3WMP 6 3WDC 7 Voltage 12 VDC 24 VDC 24 - 60 VAC 120 - 60 VAC 240 - 60 VAC Coil Options Substitute Dry taped with 24" Flying Leads 01* Free standing molded 1/4" spade 51* Free standing molded 24" Flying Leads 61* Seal Options Substitute Buna 01 Fluorocarbon 02 Polyurethane (2WNC Only) 06 Ethylene Propylene (EPR) 13 Orifice Substitute 1/32 0 3/64 1 1/16 2 5/64 3 3/32 4 1/8 5 5/32 6 *For class H coils replace second digit with 3. Example: 43 = Class H Molded with Flying Leads

Articles in this issue

Links on this page

Archives of this issue

view archives of Pneumatic & Fluid Control Catalog - z7424CT - 07 - IMI KIP Valves & Manifolds