Issue link: https://onenorgren.uberflip.com/i/552086
1 29 V-AE-32C-EM-F V-AE-32C-EMH-F V-AE-32C-EMR-F 2 3 3 1 2 3 3 1 2 3 3 1 3 2 1 3 2 1 3 2 1 3 V-32C-EM-F V-32C-EMH-F V-32C-EMR-F For further information www.norgren.com/us VALVES Symbol Port size 1, 3 2 (3) Flow (l/min) *2 1 » 2 2 » 3 Flow (l/min) *3 1 » 2 2 » 3 Material Test certificate IEC 61508 Model *1 G 1/4, G1/2 NAMUR G1/4 1250 1500 2500 3100 Aluminum x 9802505* 1/4 NPT, 1/2 NPT NAMUR 1/4 NPT 1250 1500 2500 3100 Aluminum x 9802515* G 1/2 G 1/2 1300 1200 2700 2600 Aluminum x 9802555* 1/2 NPT 1/2 NPT 1300 1200 2700 2600 Aluminum x 9802565* Technical data DIN EN 61508 IEC 61508 Approval depends on magnetic system 3/2-Way, indirectly controlled Medium: non-lubricated and dried compressed air, instrument air, nitrogen and other non- flammable neutral, dry fluids Operating pressure: 2 ... 8 bar (29 ... 116 psi) 0 ... 8 bar (0 ... 116 psi) with external air supply 2 ... 8 bar (29 ... 116 psi) Fluid/Ambient temperature: -40 ... +60°C (-40 ... +140°F) (Special-NBR) -25 ... +60°C (-13 ... +140°F) (SIL-Version) Depending on solenoid system. Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F). Materials: Housing: Aluminum 3.0615 Seal: NBR (special-NBR) Inner parts: stainless steel Technical features Suited for outdoor use under critical environment conditions Solenoid operators Flow conducted according to ISO 6358 and ISO 8778, 20°C In order to ensure full flow and proper function make sure that sufficient pressure supply with feed pipe diameters according to the port size is available. *1 Order example: To order a Series 98025 valve, with a 24Vdc coil, Model Number: 9802505076302400. Valve model code 9802505 + Coil code 076302400 = Model Number: 9802505076302400. To order the valve only, replace the * after the Valve model code from the table above with nine zero's, i.e. 9802505000000000. *2 Inlet pressure 6 bar, outlet pressure 5 bar *3 Inlet pressure 8 bar, outlet pressure 0 bar Power consumption 24 VDC 230 VAC (W) (VA) Rated current 24 VDC 230 VAC (m A) (m A) Ex-Protection Protection Class (ATEX- Category) IP-Protection According to EN60529 Temperature Ambient/ Medium (°C) Electrical connection Order separate Coil code 1.9 2.1 *5 78 11 - IP00 without Connector IP65 (with Connector) -25 ... +60 DIN EN 175 301-803 Form A *5 *6 0000000076302400 0000000076323050 076302400 076323050 0.8 - 38 - II2G II2D Ex e mb IIC T5/T6 Gb Ex tb IIIC T130°C Db IP 66 (with cable gland) -40 ... +80 T5 -40 ... +70 T6 -40 ... +80 M20 X 1.5 *6 0000000420002400 420002400 - 1.3 - 6 II2G II2D Ex e mb IIC T5/T6 Gb Ex tb IIIC T130°C Db IP 66 (with cable gland) -40 ... +80 T5 -40 ... +70 T6 -40 ... +80 M20 X 1.5 *6 0000000420123050 420123050 0.8 — 33 — II2G II2D Ex d mb IIC T5/T6 Gb Ex e mb IIC T5/T6 Gb Ex tb IIIC T130°C Db IP 66 (with cable gland) -40 ... +80 T5 -40 ... +70 T6 -40 ... +80 1/2 NPT *6 0000000460002400 460002400 — 1.3 — 6 II2G II2D Ex d mb IIC T5/T6 Gb Ex e mb IIC T5/T6 Gb Ex tb IIIC T130°C Db IP 66 (with cable gland) -40 ... +80 T5 -40 ... +70 T6 -40 ... +80 1/2 NPT *6 0000000460123050 460123050 Standard voltages (±10%) 24 VDC, 230 VAC, other voltages on request. Design according to VDE 0580, EN 50014/50028. 100% duty cycle. *5 Required connector: model 0570275 for VDC; model 0663303 for VAC, to be ordered Solenoid Voltage 200VDC! *6 Connector cable gland not supplied, see table »Accessories« Attention: The protection class for coil Series 46xx and 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb. The solenoid valves are used in ATEX zones, resulting from Protection Class Atex-category of solenoids (see table of solenoids). Model Approvals ATEX IECEx 42xx KEMA 98 ATEX 4452 X IECEx KEM 09.0068X 46xx PTB 02 ATEX 2085 X IECEx PTB 11.0094X Approvals 98025 NAMUR & Inline 3/2 poppet valves electromagnetic actuated, indirectly controlled G 1/2, 1/2 NPT & NAMUR interface