Issue link: https://onenorgren.uberflip.com/i/552086
28 1 For further information www.norgren.com/us VALVES Connector, Form A Silencer *1 (plastic) Silencer (stainless steel) *1 Exhaust guard *2 0570275000000000 M/S2 (G1/4) 0014613000000000 (G 1/4) 0613422000000000 (suitable for 1/4" NPT or G1/4") M/S4 (G1/2) 0613423000000000 (suitable for 1/2" NPT or G1/2") Cable gland Ex-Protection. Ex d (ATEX). Nickel. plated brass Model Thread Cable Ø Material Protection class (ATEX) 0588819000000000 M 20x1.5 5.0...8.0 mm Nickel plated brass II2GD Ex e 0588851000000000 M 20x1.5 10...14 mm Nickel plated brass II2GD Ex d 0588925000000000 1/2-14-NPT 7.5...11.9 mm Nickel plated brass II2GD Ex d Accessories *1 For indoors use only *2 For outdoors use ~0,2 (bar) Model Approvals ATEX IECEx FM 42xx KEMA 98 ATEX 4452 X IECEx KEM 09.0068X 46xx PTB 02 ATEX 2085 X IECEx PTB 11.0094X Approvals 26360 & 80207 Inline/NAMUR Solenoid operators and accessories Power consumption 24 VDC 230 VAC (W) (VA) Rated current 24 VDC 230 VAC (m A) (m A) Ex- Protection Protection Class (ATEX- Category) IP-Protection According to EN60529 Temperature Ambient/ Medium (°C) Electrical connection Order separate Coil code 2.7 - 113 - - IP 65 (with Connector) -25 ... +60 Fluid: max. 80 Connector DIN EN 175301-803 Form A* 6 0000000024202400 024202400 - 4.2 - - - IP 65 (with Connector) -25 ... +60 Fluid: max. 80 Connector DIN EN 175301-803 Form A* 6 0000000024523050 024523050 3.9 - 162 - II2G II2D Ex e mb IIC T4/T6 Gb Ex tb IIIC T130°C Db IP 66 (with cable gland) -40 ... +80 T4 -40 ... +55 T6 -40 ... +80 M20 x 1.5* 6 0000000421002400 421002400 - 5.3 - 23 II2G II2D Ex e mb IIC T4/T6 Gb Ex tb IIIC T130°C Db IP 66 (with cable gland) -40 ... +80 T4 -40 ... +55 T6 -40 ... +80 M20 x 1.5* 6 0000000421123050 421123050 3.9 - 162 - II2G II2D Ex d mb IIC T4/T6 Gb Ex e mb IIC T4/T6 Gb Ex tb IIIC T130°C Db IP 66 (with cable gland) -40 ... +80 T4 -40 ... +55 T6 -40 ... +80 1/2-14 NPT* 6 0000000461002400 461002400 - 5.3 - 23 II2G II2D Ex d mb IIC T4/T6 Gb Ex e mb IIC T4/T6 Gb Ex tb IIIC T130°C Db IP 66 (with cable gland) -40 ... +80 T4 -40 ... +55 T6 -40 ... +80 1/2-14 NPT* 6 0000000461123050 461123050 3.9 - 162 - II2G II2D Ex d mb IIC T4/T6 Gb Ex e mb IIC T4/T6 Gb Ex tb IIIC T130°C Db IP 66 (with cable gland) -40 ... +80 T4 -40 ... +55 T6 -40 ... +80 M20 x 1.5* 6 0000000461202400 461202400 - 5.3 - 23 II2G II2D Ex d mb IIC T4/T6 Gb Ex e mb IIC T4/T6 Gb Ex tb IIIC T130°C Db IP 66 (with cable gland) -40 ... +80 T4 -40 ... +55 T6 -40 ... +80 M20 x 1.5* 6 0000000461323050 461323050 Solenoid operators Standard voltages (±10%) 24 VDC, 230 VAC, other voltages on request. Design according to VDE 0580, EN 50014/50028. 100% duty cycle. *6 Connector cable gland not supplied see table, "Accessories" Attention: The protection class for coil Series 46xx or 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb.