50 1 3 2 1 3 2 1 3 2 1 3 V-32C-E-F V-32C-EH-F V-32C-ER-F FM APPROVED 2 4 1 5 3 2 4 1 5 3 2 4 1 5 3 V-52-E-F V-52-EH-F V-52-EH-F For further information www.norgren.com/us VALVES Symbol Model Port size Function Operating pressure (bar) Material Seat seal Manual override/ reset ATEX certification Power consumption 24 VDC (W) Ambient temperature Y123AA1H1BS 1/4 NPT 3/2 UNI 0 ... 20 NBR Without Exd IIC T6 4.5 T6 (-60 … +48°C), T4 (-60 ... +90°C ) Y123AA3H1BS 1/2 NPT 3/2 UNI 0 ... 20 NBR Without Exd IIC T6 9.6 T6 (-60 … +48°C), T4 (-60 ... +90°C ) Y125AA3H1BS 1/4 NPT 5/2 UNI 0 ... 20 NBR Without Exd IIC T6 9.6 T6 (-60 … +48°C), T4 (-60 ... +90°C ) Technical data – standard models with conduit connection M20 x 1,5 Medium: Hydraulic and pneumatic – customer to specify and confirm compatibility Operating pressure: 0 ... 20 bar (0 ... 290 psi) Fluid temperature: -20 ... +90°C (-4 ... +194°F) Options to -60°C (-76°F) Ambient temperature: See table. Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F) Materials: Valve body, trim, coil housing and top cover: stainless steel 1.4404 (316 L) O-rings seats & seals: high NBR Technical features ICO4S 3/2 or 5/2 poppet valves electromagnetic actuated, directly controlled. 1/4 NPT Reliable and long life, ideal for a one time installation