1 49 FM APPROVED 3 2 1 3 2 1 3 2 1 3 V-32C-E-F V-32C-EH-F V-32C-ER-F 2 4 1 5 3 2 4 1 5 3 2 4 1 5 3 V-52-E-F V-52-EH-F V-52-EH-F For further information www.norgren.com/us VALVES Symbol Model Port size Function Operating pressure (bar) Manual override/ reset ATEX certification Power consumption at 24 Vdc (W) Ambient temperature Y013AA1H1BS 1/4 NPT 3/2 UNI 0 ... 12 Without Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) Y013AA3H1BS 1/2 NPT 3/2 UNI 0 ... 12 Without Ex II 2 GD, Exd IIC 7.8 T6 (-55 … +50°C), T4 (+90°C max) Y015AA1H1BS 1/4 NPT 5/2 UNI 0 ... 12 Without Ex II 2 GD, Exd IIC 7.8 T6 (-55 … +50°C), T4 (+90°C max) Y015AA3H1BS 1/2 NPT 5/2 UNI 0 ... 12 Without Ex II 2 GD, Exd IIC 7.8 T6 (-55 … +50°C), T4 (+90°C max) Technical data – standard models with conduit connection M20 x 1,5 Reliable and long life, ideal for a one time installation Medium: Hydraulic and pneumatic – customer to specify and confirm compatibility Operating pressure: 0 ... 12 bar (0 ... 174 psi) Fluid temperature: -55 ... +90°C (-67 ... +194°F) Ambient temperature: See table. Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F) Materials: Valve body, trim, coil housing and top cover: stainless steel 1.4404 (316 L) O-rings seats & seals: NBR Other seal materials available on request Technical features ICO3S 3/2 or 5/2 poppet valves Electromagnetically actuated, direct solenoid operated. 1/4 NPT ... 1/2 NPT