Issue link: https://onenorgren.uberflip.com/i/552086
1 25 4 2 3 1 5 V-32spec-EM-F V-32spec-EMH-F V-32spec-EMR-F 4 2 3 1 5 4 2 3 1 5 2 4 1 5 3 2 4 1 5 3 2 4 1 5 3 V-52-EM-F V-52-EMH-F V-52-EMH-F V-32spec-EM-EM V-32spec-EMH-EMH V-32spec-EMR-EMR 4 2 3 1 5 4 2 3 1 5 4 2 3 1 5 2 4 1 5 3 2 4 1 5 3 1 5 3 2 4 V-52B-EM V-52B-EMH V-52B-EMR For further information www.norgren.com/us VALVES Symbol Port size 1, 3, 5 2, 4 Actuation/Return Operating pressure (bar) *2 Flow (l/min) Valve model code *1 G 1/4 Flange Solenoid/Spring 2 ... 8 1230 9730000* 1/4 NPT Flange Solenoid/Spring 2 ... 8 1230 9730010* G 1/4 Flange Solenoid/Solenoid 2 ... 8 1250 9731000* 1/4 NPT Flange Solenoid/Solenoid 2 ... 8 1250 9731010* Power consumption 24 VDC 230 VAC (W) (VA) Ex- Protection Protection Class (ATEX- Category) IP-Protection According to EN60529 Temperature Ambient/Medium (°C) Order separetely Coil code 1.8 4.3 - IP 65 (with Connector) DIN EN 175301-803 Form B *6 -15 ... +50 0000000305002400 0000000305023050 305002400 305023050 1.6 3.5 - IP 65 (with Connector) DIN EN 175301-803 Form A *6 -15 ... +50 0000000303602400 0000000303623050 303602400 303623050 2.7 - II2G II2D Ex mb IIC T5 Gb Ex mb tb T95°C Db IP 65 (with 3 m cable) -20 ... +50 0000000306202400 306202400 - 2.1 II2G II2D Ex mb IIC T5 Gb Ex mb tb T95°C Db IP 65 (with 3 m cable) -20 ... +50 0000000306323050 306323050 Connector DIN EN 175301-803 Silencer *1 (plastic) Exhaust guard *2 0570275000000000, Form A C/S2 (1/4 NPT) 0613422000000000 (suitable for 1/4" NPT or G1/4") 0680003000000000, Form B M/S2 (G 1/4) Approval depends on magnetic system 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled, standard model *1 Order example: To order a Series 97300 valve, with a 24Vdc coil, Model Number: 9730000305002400. Valve model code 9730000 + Coil code 305002400 = Model Number: 9730000305002400. To order the valve only, replace the * after the Valve model code from the table above with nine zero's, i.e. 9730000000000000. *2 Below -10°C must be > 2.5 bar Solenoid operators Ex e mb IIC T4 Gb Ex tb IIIC T120°C Db I IP 65 (with cable gland) Standard voltages (±10%) 24 VDC, 230 VAC, other voltages on request. *6 Connector is not scope of delivery, see table »Accessories« Medium: Filtered, lubricated or non-lubricated and dry compressed air Operating pressure: 2 ... 8 bar (29 ... 116 psi) (below -10°C >must be > 2,5 bar (36psi)) Fluid/Ambient temperature: -15 ... +50°C (-5 ... +122°F) Depending on solenoid system. Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F). Materials: Housing: Aluminum anodized Pilot flange: Pilot flange: Plastic (PBT) Flange plate: Aluminum Seals: NBR Technical features Manual override with detent Technical data *1 For indoors use only *2 For outdoors use ~ 0.2 (bar) Accessories The solenoid valves are used in ATEX- zones, resulting from Protection Class Atex-category of solenoids (see table of solenoids). Model Approval ATEX 306x PTB 03 ATEX 2015 Approval 97300 NAMUR 3/2- & 5/2-Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, flanged with NAMUR interface