Norgren Collateral

z7411CT - Distributor Process catalog

Issue link: https://onenorgren.uberflip.com/i/552086

Contents of this Issue

Navigation

Page 26 of 100

26 1 3 2 1 3 3 2 1 3 3 2 1 3 V-32C-EM-S V-32C-EMH-S V-32C-EMH-S 2 4 1 5 3 2 4 1 5 3 2 4 1 5 3 V-52-EM-S V-52-EMH-S V-52-EMH-S 2 4 1 5 3 2 4 1 5 3 1 5 3 2 4 V-52B-EM V-52B-EMH V-52B-EMR For further information www.norgren.com/us VALVES Symbol Port size *1 Operating pressure (bar) Flow (l/min) Manual override with detent Valve model *2 G 1/4 1 ... 10 1200 with 8020765* G 1/2 1.5 ... 10 3000 with 8020865* Symbol Port size *1 Operating pressure (bar) Flow (l/min) Manual override with detent Valve model *2 G 1/4 1 ... 10 1200 with 2636065* G 1/2 2 ... 10 3000 with 2637065* G 1/4 1 ... 10 1200 with 2636265* G 1/2 2 ... 10 3000 with 2637265* Approval depends on magnetic system 3/2-Way Medium: Filtered, lubricated or non-lubricated Air Operating pressure: 1 ... 10 bar (14 ...145 psi); G 1/4 1,5 ... 10 bar (21 ...145 psi); G 1/2 2 ... 10 bar (29 ...145 psi); G 1/2 Fluid/Ambient temperature: -10 ... +60°C (+14 ... +140°F) -20°C (-4°F) on request Depending on solenoid system. Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F). Materials: Housing: aluminum anodized Pilot flange: plastic (POM) Seals: NBR Technical features Technical data 5/2-Way *1 NPT versions may be available upon request. Contact technical support. *2 Order example: To order a Series 26360 valve, with a 24Vdc coil, Model Number: 2636065024202400. Valve model code 2636065 + Coil code 024202400 = Model Number: 2636065024202400. To order the valve only, replace the * after the Valve model code from the table above with nine zero's, i.e. 2636065000000000. *1 NPT versions may be available upon request. Contact technical support. *2 Order example: To order a Series 80207 valve, with a 24Vdc coil, Model Number: 8020765024202400. Valve model code 8020765 + Coil code 024202400 = Model Number: 8020765024202400. To order the valve only, replace the * after the Valve model code from the table above with nine zero's, i.e. 8020765000000000. Manual override with and without detent The solenoid valves are used in ATEX- zones, resulting from Protection Class Atex-category of solenoids (see table of solenoids). 26360 & 80207 Inline 3/2- & 5/2-Spool valves electromagnetic actuated, indirectly controlled G 1/4, G 1/2

Articles in this issue

Links on this page

Archives of this issue

view archives of Norgren Collateral - z7411CT - Distributor Process catalog