Norgren Collateral

z7420BR - Valve Circuit Guide

Issue link: https://onenorgren.uberflip.com/i/508614

Contents of this Issue

Navigation

Page 21 of 26

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. © 2015 Norgren, Inc. Simplified Valve Circuit Guide 20 Cylinder Control-One Cycle, Starts of First Operation. (Poppet Valves Shown) The cylinder will cycle once regardless of multiple start signals or how long the manual valve is actuated. Time of cylinder cycle adjustment is up to one minute. Circuit consists of a Norgren 4-way valve with a -23 time delay and a shuttle valve. Time Delay on Extension of Cylinder. (Poppet and Spool Valves Shown) The cylinder extension can be delayed up to one minute after the manual valve has been actuated by using a Norgren T.D.O. (-"01"=0-5 seconds, or "03" = 0-60 seconds) time delay and a 4-way valve. CYLINDER MANUAL VALVE 1 2 3 10 12 IN EX CYL. 1 CYL. 2 TIME DELAY NORGREN 4-WAY POPPET VALVE -23 CYLINDER MANUAL VALVE 1 2 3 10 12 IN EX CYL. 1 CYL. 2 TIME DELAY NORGREN 4-WAY POPPET VALVE -01 OR -03