Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document. © 2015 Norgren, Inc.
Simplified Valve Circuit Guide
20
Cylinder Control-One Cycle, Starts of First
Operation.
(Poppet Valves Shown)
The cylinder will cycle once regardless of multiple start signals
or how long the manual valve is actuated. Time of cylinder cycle
adjustment is up to one minute.
Circuit consists of a Norgren 4-way valve with a -23 time delay
and a shuttle valve.
Time Delay on Extension of Cylinder.
(Poppet and Spool Valves Shown)
The cylinder extension can be delayed up to one minute after
the manual valve has been actuated by using a Norgren T.D.O.
(-"01"=0-5 seconds, or "03" = 0-60 seconds) time delay and a
4-way valve.
CYLINDER
MANUAL
VALVE
1
2
3
10
12
IN
EX
CYL. 1
CYL. 2
TIME DELAY
NORGREN
4-WAY
POPPET
VALVE
-23
CYLINDER
MANUAL
VALVE
1
2
3
10
12
IN
EX
CYL. 1
CYL. 2
TIME DELAY
NORGREN
4-WAY
POPPET
VALVE
-01
OR
-03