Norgren Collateral

z7420BR - Valve Circuit Guide

Issue link: https://onenorgren.uberflip.com/i/508614

Contents of this Issue

Navigation

Page 20 of 26

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. © 2015 Norgren, Inc. Simplified Valve Circuit Guide 19 Cylinder Control Transfer. (Spool Valve Shown) This circuit allows only one cylinder to be operative at a time. Use of a 3-way valve for transfer control causes the cylinders to remain in their last position when control has been transferred (pressure is not exhausted). The use of a 4-way valve for transfer control will cause the cylinder to be free floating when control has been transferred (pressure is exhausted). Cylinder Feed Rate Control with Positive Lock in any Cylinder Position. (Spool Valves Shown) (Air over Oil cylinder) This circuit provides a constant cylinder feed rate for both directions of travel. In addition, the cylinder will lock in position when the manual valve is centered. Air provides the force to move the cylinder; oil, with its feature of non- compressibility, is used to give smooth cylinder motion. 1 2 14 CYLINDER NO. 1 4 12 3 5 CONTROL VALVE 1 2 14 CYLINDER NO. 2 4 12 3 5 CONTROL VALVE 1 3 12 10 2 TRANSFER VALVE 3-WAY SHOWN 2 1 10 12 OIL AIR CYLINDER MANUAL VALVE 12 2 4 3 1 5 14

Articles in this issue

Archives of this issue