Norgren Collateral

z7420BR - Valve Circuit Guide

Issue link: https://onenorgren.uberflip.com/i/508614

Contents of this Issue

Navigation

Page 10 of 26

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. © 2015 Norgren, Inc. Simplified Valve Circuit Guide 9 Air Clamp, Controlled Force. (Spool Valve Shown) Cylinder clamping force can be controlled by a separate regu- lator when used with a dual pressure valve. (Port 1 becomes exhaust.) Interlock Circuit. (Spool Valves Shown) The cylinders can be either air spring or spring return. The cylinders are interlocked with the pressure extending one cylinder, disabling the other cylinder circuit. One cannot be extended as long as pressure is applied to the other *Regulator relief flow must be sufficient to accommodate the cylinder speed. Flow controls will allow variations of cylinder extension speed. 1 2 14 CYLINDER 4 12 5 MANUAL VALVE P s 3 1 2 3 1 2 3 2 3 2 3 CYLINDER NO. 1 CYLINDER NO.2 MANUAL VALVE NO. 1 MANUAL VALVE NO. 2 P s 1 1

Articles in this issue

Archives of this issue

view archives of Norgren Collateral - z7420BR - Valve Circuit Guide