54 1 P A P A For further information www.imi-precision.com VALVES Symbol Model Port size Orifice (mm) Valve length (mm) Kv-value *1) (m 3 /h) Operating pressure (bar) 8296300.8171.xxxxx G3/4 20 95 18 0.4 ... 8 8297300.8171.xxxxx 3/4 NPT 20 95 18 0.4 ... 8 8296400.8171.xxxxx G1 25 95 22 0.4 ... 8 8297400.8171.xxxxx 1 NPT 25 95 22 0.4 ... 8 8296600.8171.xxxxx G1 1/2 40 135 59 0.4 ... 8 8297600.8171.xxxxx 1 1/2 NPT 40 135 59 0.4 ... 8 8296700.8171.xxxxx G2 50 169 80 0.4 ... 8 8297700.8171.xxxxx 2 NPT 50 169 80 0.4 ... 8 8296800.8171.xxxxx G2 1/2 65 169 93 0.4 ... 8 8297800.8171.xxxxx 2 1/2 NPT 65 169 93 0.4 ... 8 8296900.8171.xxxxx G3 80 239,5 172 0.4 ... 7 Medium: Compressed air Flow direction: Fixed Operating pressure: 0,4 ... 7/8 bar (5,8 ... 101/116 psi) Fluid temperature: -40...+85°C (-40 ... +185°F) Ambient temperature: –20 ... +85°C (-4 ... +185°F) Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F). Materials: Body: Aluminum Seat Seal: TPE Internal Parts: TPU Technical features Solenoid interchangeable without tools (Twist-on) Easy to maintain Technical features - Standard models xxxxx Please insert voltage and frequency codes *1) Cv-value (US) ≈ kv value x 1,2 Solenoid operators Design DIN VDE 0580 Voltage range ±10% Duty cycle 100% ED Protection EN 60529 IP65 Connector Form A to DIN EN 175301-803 (included) Electrical details for all solenoid systems Voltage and Frequency Solenoid 8171 *1) Code Voltage Code Frequency Voltage Frequency Power consumption Inrush- Holding- power power 024 00 24 V DC - 12 W 12 W 024 50 24 V AC 50 Hz 23 VA 16 VA 110 50 110 V AC 50 Hz 23 VA 16 VA 120 60 120 V AC 60 Hz 23 VA 16 VA 230 50 230 V AC 50 Hz 23 VA 16 VA ATEX Category Protection Solenoid Standard voltage II3GD EEx nA II T4 T 135°C 8176 24 V DC, 110 V AC, 230 V AC II2GD EEx me II T4 T 140°C 8186 24 V DC, 110 V AC, 230 V AC Additional solenoid systems *1) Voltage Option Solenoid Standard voltage Solenoid version for low temperature = 40°C 9151 24 V DC, 110 V AC, 230 V AC Pulse Solenoid 8821 24 V DC, 110 V AC, 230 V AC Solenoid version for low temperature = 40°C 8001 24 V DC, 110 V AC, 230 V AC Additional solenoid systems According to DIN VDE 0580 at a solenoid temperature of +20°C. At elevated temperatures, the power of the solenoid coil could be reduced by up to 30%. Attention! The conditions imposed on the Ex approvals lead to reduction of the permissible standard temperature ranges in the cases of explosion protected solenoids. 82960, 82970 2/2-way diaphragm valves G3/4 ... 3, 3/4 ... 2 1/2 NPT

Articles in this issue

Archives of this issue

view archives of Norgren Collateral - z7910CT - Express Process catalog