1 53 P A P A For further information www.imi-precision.com VALVES Symbol Model Orifice (mm) Port size Kv-value (m 3 /h) Operating pressure (bar) 8254000.9150.00000 8 G1/4 1.9 0…10 8254100.9150.00000 10 G3/8 3 0…10 8254200.9150.00000 12 G1/2 3.4 0…10 8254300.9150.00000 20 G3/4 5.8 0…10 8254400.9150.00000 25 G1 8 0…10 Symbol Model Orifice (mm) Port size Kv-value (m 3 /h) Operating pressure (bar) 8259000.9150.00000 8 G1/4 1.9 0…10 8259100.9150.00000 10 G3/8 3 0…10 8259200.9150.00000 12 G1/2 3.4 0…10 8259300.9150.00000 20 G3/4 5.8 0…10 8259400.9150.00000 25 G1 8 0…10 Models - Brass Models - Stainless steel Medium: Neutral gases and liquids (82540) Slightly aggressive, gases and liquids (82590) Flow direction: Fixed Operating pressure: 0 … 10 bar (0 ... 145 psi) Temperatur: Fluid –10°C … +90°C (14 ... +194°F) max. Ambient –10°C … +50°C (14 ... +122°F) max. Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F). Materials: Body: Brass (82540) Stainless steel (82590) Seat Seal: NBR-K Internal Parts: Stainless steel, PVDF, Brass For contaminated fluids installations of an upstream filter is recommended. Technical features Solenoid interchangeable without tools (Click-on ® ) Other functions and operating voltages available on request Solenoid operators Design DIN VDE 0580 Voltage range ±10% Duty cycle 100% ED Protection EN 60529 IP65 Connector Form A to DIN EN 175301-803 (included) Electrical details for all solenoid systems Voltage and Frequency Solenoid 9151/9154 *1) Code Voltage Code Frequency Voltage Frequency Power consumption Inrush- Holding- power power 024 00 24 V DC - 18 W 18 W 024 50 24 V AC 50 Hz 20 VA 20 VA 110 50 110 V AC 50 Hz 20 VA 20 VA 120 60 120 V AC 60 Hz 20 VA 20 VA 230 50 230 V AC 50 Hz 20 VA 20 VA Voltage and Frequency Solenoid 9301/9304 *1) 024 00 24 V DC - 18 W 18 W 024 50 24 V AC 50 Hz 20 VA 20 VA 110 50 110 V AC 50 Hz 20 VA 20 VA 120 60 120 V AC 60 Hz 20 VA 20 VA 230 50 230 V AC 50 Hz 20 VA 20 VA Voltage and Frequency Solenoid 9401/9404 *1) 024 00 24 V DC - 38 W 38 W 024 49 24 V AC 40 ... 60 Hz 42 VA 42 VA 110 49 110 V AC 40 ... 60 Hz 42 VA 42 VA 120 49 120 V AC 40 ... 60 Hz 42 VA 42 VA 230 49 230 V AC 40 ... 60 Hz 42 VA 42 VA ATEX Category Protection Solenoid Standard voltage II2GD EEx me II T3 T 140°C 9356 24 V DC, 110 V AC, 230 V AC II3GD EEx nA II T4 T 135°C 9326 24 V DC, 110 V AC, 230 V AC II3GD EEx nA II T4 T 135°C 8426 24 V DC, 110 V AC, 230 V AC II2GD EEx me II T3 T 140°C 8441 24 V DC, 110 V AC, 230 V AC II3GD EEx nA II T4 T 135°C 9176 24 V DC, 110 V AC, 230 V AC II2GD EEx me II T3 T 140°C 9191 24 V DC, 110 V AC, 230 V AC II3GD EEx nA II T4 T 135°C 9426 24 V DC, 110 V AC, 230 V AC Additional solenoid systems *1) Voltage Buschjost 82540 & 82590 Solenoid actuated diaphragm valve with forced lifting 2/2 N/C, G1/4…G1 According to DIN VDE 0580 at a solenoid temperature of +20°C. At elevated temperatures, the power of the solenoid coil could be reduced by up to 30%. Attention! The conditions imposed on the Ex approvals lead to reduction of the permissible standard temperature ranges in the cases of explosion protected solenoids.

Articles in this issue

Archives of this issue

view archives of Norgren Collateral - z7910CT - Express Process catalog