Datasheets

V60...V63 Solenoid and Pilot Actuated Spool Valves

Norgren Featured Datasheets

Issue link: https://onenorgren.uberflip.com/i/1475136

Contents of this Issue

Navigation

Page 4 of 19

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2019 - 9261a) © 2015 IMI International s.r.o. en 8.200.160.05 08/22 5/2 directional control valves, pilot actuated Symbol Port size Actuation Flow (l/min) Operating pressure (bar) Pilot pressure external (bar) Weight (kg) Drawing No. Model 2 12 14 4 1 5 3 1/8 NPT Air/Spring 0.76 (750) -13 ... 145 (-0.9 ... 10) 36 ... 145 (2.5 ... 10) 0.35 (0.16) 40 V60P5D7A-XP0900 1/4 NPT Air/Spring 1.32 (1300) -13 ... 145 (-0.9 ... 10) 36 ... 145 (2.5 ... 10) 0.57 (0.26) 40 V61R5D7A-XP0900 3/8 NPT Air/Spring 2.62 (2600) -13 ... 145 (-0.9 ... 10) 36 ... 145 (2.5 ... 10) 1.23 (0.56) 41 V62S5D7A-XP0900 1/2 NPT Air/Spring 4.52 (4500) -13 ... 145 (-0.9 ... 10) 44 ... 232 (3 ... 16) 2.03 (0.92) 42 V63D5D7A-XP0900 2 12 14 4 1 5 3 1/8 NPT Air/Air 0.76 (750) -13 ... 145 (-0.9 ... 10) 22 ... 145 (1.5 ... 10) 0.37 (0.17) 43 V60P5DDA-XP0200 1/4 NPT Air/Air 1.32 (1300) -13 ... 145 (-0.9 ... 10) 22 ... 145 (1.5 ... 10) 0.59 (0.27) 43 V61R5DDA-XP0200 3/8 NPT Air/Air 2.62 (2600) -13 ... 145 (-0.9 ... 10) 22 ... 145 (1.5 ... 10) 1.28 (0.58) 44 V62S5DDA-XP0200 1/2 NPT Air/Air 4.52 (4500) -13 ... 232 (-0,9 ... 16) 22 ... 232 (1.5 ... 16) 1.92 (0.87) 45 V63D5DDA-XP0200 5/3 directional control valves, pilot actuated Symbol Port size Function Actuation Flow (l/min) Operating pressure (bar) Pilot pressure external (bar) Weight (kg) Drawing No. Model 4 2 5 1 3 12 14 1/8 NPT APB Air/Air 0.51 (500) -13 ... 145 (-0.9 ... 10) 44 ... 145 (3 ... 10) 0.44 (0.20) 46 V60P6DDA-XP0200 1/4 NPT APB Air/Air 0.97 (950) -13 ... 145 (-0.9 ... 10) 44 ... 145 (3 ... 10) 0.71 (0.32) 46 V61R6DDA-XP0200 3/8 NPT APB Air/Air 1.93 (1900) -13 ... 145 (-0.9 ... 10) 44 ... 145 (3 ... 10) 1.47 (0.67) 47 V62S6DDA-XP0200 1/2 NPT APB Air/Air 2.32 (2300) -13 ... 145 (-0.9 ... 10) 44 ... 145 (3 ... 10) 2.43 (1.10) 48 V63D6DDA-XP0200 4 2 5 1 3 12 14 1/8 NPT COE Air/Air 0.51 (500) -13 ... 145 (-0.9 ... 10) 44 ... 145 (3 ... 10) 0.44 (0.20) 46 V60P7DDA-XP0200 1/4 NPT COE Air/Air 0.97 (950) -13 ... 145 (-0.9 ... 10) 44 ... 145 (3 ... 10) 0.71 (0.32) 46 V61R7DDA-XP0200 3/8 NPT COE Air/Air 1.93 (1900) -13 ... 145 (-0.9 ... 10) 44 ... 145 (3 ... 10) 1.47 (0.67) 47 V62S7DDA-XP0200 1/2 NPT COE Air/Air 2.32 (2300) -13 ... 145 (-0.9 ... 10) 44 ... 145 (3 ... 10) 2.43 (1.10) 48 V63D7DDA-XP0200 4 2 5 1 3 12 14 1/8 NPT COP Air/Air 0.51 (500) -13 ... 145 (-0.9 ... 10) 44 ... 145 (3 ... 10) 0.44 (0.20) 46 V60P8DDA-XP0200 1/4 NPT COP Air/Air 0.97 (950) -13 ... 145 (-0.9 ... 10) 44 ... 145 (3 ... 10) 0.71 (0.32) 46 V61R8DDA-XP0200 3/8 NPT COP Air/Air 1.93 (1900) -13 ... 145 (-0.9 ... 10) 44 ... 145 (3 ... 10) 1.47 (0.67) 47 V62S8DDA-XP0200 NO = Normally open NC/NC = Both valves normally closed (port P) NO/NO = Both valves normally open (port P) NO/NC = Valve normally open, 1 valve normally closed (port P) APB = All ports blocked COE = Center open exhaust COP = Center open pressure

Articles in this issue

Archives of this issue

view archives of Datasheets - V60...V63 Solenoid and Pilot Actuated Spool Valves