Datasheets

V60...V63 Solenoid and Pilot Actuated Spool Valves

Norgren Featured Datasheets

Issue link: https://onenorgren.uberflip.com/i/1475136

Contents of this Issue

Navigation

Page 3 of 19

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2019 - 9261a) © 2015 IMI International s.r.o. en 8.200.160.04 08/22 3/2 directional control valves, pilot actuated Symbol Port size Function Actuation Flow Cv (l/min) Operating pressure psi (bar) Pilot pressure external psi (bar) Weight lbs (kg) Drawing No. Model 1 2 10 12 3 1/8 NPT NC Air/Spring 0.76 (750) -13 ... 145 (-0.9 ... 10) 36 ... 145 (2.5 ... 10) 0.29 (0.13) 31 V60P4D7A-XP0900 1/4 NPT NC Air/Spring 1.32 (1300) -13 ... 145 (-0.9 ... 10) 36 ... 145 (2.5 ... 10) 0.46 (0.21) 31 V61R4D7A-XP0900 3/8 NPT NC Air/Spring 2.64 (2600) -13 ... 145 (-0.9 ... 10) 36 ... 145 (2.5 ... 10) 0.95 (0.43) 33 V62S4D7A-XP0900 3 2 12 10 1 3 1/8 NPT NO Air/Spring 0.76 (750) -13 ... 145 (-0.9 ... 10) 36 ... 145 (2.5 ... 10) 0.29 (0.13) 32 V60P3D7A-XP0900 1/4 NPT NO Air/Spring 1.32 (1300) -13 ... 145 (-0.9 ... 10) 36 ... 145 (2.5 ... 10) 0.46 (0.21) 32 V61R3D7A-XP0900 3/8 NPT NO Air/Spring 2.64 (2600) -13 ... 145 (-0.9 ... 10) 36 ... 145 (2.5 ... 10) 0.95 (0.43) 34 V62S3D7A-XP0900 1 2 10 12 3 1/8 NPT NC Air/Air 0.76 (750) -13 ... 145 (-0.9 ... 10) 22 ... 145 (1.5 ... 10) 0.29 (0.13) 37 V60P4DDA-XP0200 1/4 NPT NC Air/Air 1.32 (1300) -13 ... 145 (-0.9 ... 10) 22 ... 145 (1.5 ... 10) 0.46 (0.21) 37 V61R4DDA-XP0200 3/8 NPT NC Air/Air 2.64 (2600) -13 ... 145 (-0.9 ... 10) 22 ... 145 (1.5 ... 10) 0.95 (0.43) 38 V62S4DDA-XP0200 2 x 3/2 directional control valves, pilot actuated Symbol Port size Function Actuation Flow Cv (l/min) Operating pressure psi (bar) Pilot pressure external psi (bar) Weight lbs (kg) Drawing No. Model 2 3 4 14 10 10 12 1 5 1/8 NPT NC/NC Air/Air 0.51 (500) 29 ... 145 (2 ... 10) 29 ... 145 (2 ... 10) 0.40 (0.18) 43 V60PADDA-XP0200 1/4 NPT NC/NC Air/Air 0.97 (950) 29 ... 145 (2 ... 10) 29 ... 145 (2 ... 10) 0.62 (0.28) 43 V61RADDA-XP0200 3/8 NPT NC/NC Air/Air 1.93 (1900) 29 ... 145 (2 ... 10) 29 ... 145 (2 ... 10) 1.32 (0.60) 44 V62SADDA-XP0200 2 3 4 1 5 10 14 12 10 1/8 NPT NO/NO Air/Air 0.51 (500) 29 ... 145 (2 ... 10) 29 ... 145 (2 ... 10) 0.40 (0.18) 43 V60PBDDA-XP0200 1/4 NPT NO/NO Air/Air 0.97 (950) 29 ... 145 (2 ... 10) 29 ... 145 (2 ... 10) 0.62 (0.28) 43 V61RBDDA-XP0200 3/8 NPT NO/NO Air/Air 1.93 (1900) 29 ... 145 (2 ... 10) 29 ... 145 (2 ... 10) 1.32 (0.60) 44 V62SBDDA-XP0200 2 3 4 1 5 10 14 10 12 1/8 NPT NO/NC Air/Air 0.51 (500) 29 ... 145 (2 ... 10) 29 ... 145 (2 ... 10) 0.40 (0.18) 43 V60PCDDA-XP0200 1/4 NPT NO/NC Air/Air 0.97 (950) 29 ... 145 (2 ... 10) 29 ... 145 (2 ... 10) 0.62 (0.28) 43 V61RCDDA-XP0200 3/8 NPT NO/NC Air/Air 1.93 (1900) 29 ... 145 (2 ... 10) 29 ... 145 (2 ... 10) 1.32 (0.60) 44 V62SCDDA-XP0200 NC = Normally closed NO = Normally open NC/NC = Both valves normally closed (port P) NO/NO = Both valves normally open (port P) NO/NC = Valve normally open, 1 valve normally closed (port P) APB = All ports blocked COE = Center open exhaust COP = Center open pressure

Articles in this issue

Archives of this issue

view archives of Datasheets - V60...V63 Solenoid and Pilot Actuated Spool Valves