Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document. (2019 - 9261a) © 2015 IMI International s.r.o. en 3.6.001.07 06/22
IO-Link Master with PROFINET Interface IO-Link Master with EtherNet/IP Interface
Model NC-MP-4A4B-12DLA NC-ME-4A4B-12DLA
Tests/Approvals
EMC EN 61000-6-2
EN 61000-6-4
Shock resistance DIN EN 60068-2-27
Vibration resistance DIN EN 60068-2-64 2009-04
DIN EN 60068-2-6 2008-10
MTTF (years) 46
Mechanical data
Weight oz (g) 14.54 (412.1)
Materials housing: PA; socket: brass nickel-plated
Electrical connection - Ethernet
IN/OUT XF1, XF2
1 TX +
2 RX +
3 TX -
4 RX -
5 not used
Connector: M12
4
2
3
1
5
Electrical connection - Process connection
IO-Link Port Class B X1...X4
1 Sensor supply (US) L +
2 digital output (UA) L+
3 Sensor supply (US) L-
4 C/Q IO-Link
5 actuator supply (UA) L-
IO-Link Port Class A X5...X8
1 Sensor supply (US) L+
2 digital input (US)
3 Sensor supply (US) L-
4 C/Q IO-Link
5 not used
Connector: M12
2
3
4
1
5
Electrical connection - voltage supply IN
XD1
1 + 24 V DC (US) brown
2 GND (UA) white
3 GND (US) blue
4 + 24 V DC (UA) black
5 FE grey
Connector: M12
5
4
3
2
1
Electrical connection - voltage supply OUT
XD2
1 + 24 V DC (US) brown
2 GND (UA) white
3 GND (US) blue
4 + 24 V DC (UA) black
5 FE grey
Connector: M12
5
3
1
2
4