Datasheets

NC_Series_IOLink_Masters_Datasheet

Norgren Featured Datasheets

Issue link: https://onenorgren.uberflip.com/i/1471220

Contents of this Issue

Navigation

Page 5 of 31

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2019 - 9261a) © 2015 IMI International s.r.o. en 3.6.001.06 06/22 IO-Link Masters Technical Data IO-Link Master with PROFINET Interface IO-Link Master with EtherNet/IP Interface Model NC-MP-4A4B-12DLA NC-ME-4A4B-12DLA Application Application I/O modules for field applications Daisy-chain function voltage supply; Ethernet interface Electrical data Operating voltage (V) 20...30 DC; (US; to SELV/PELV) Current consumption (mA) 300...3900; (US) Protection class III Additional voltage supply (V) 20...30 DC; (UA) Actuator supply UA Max. current load total (A) 8 Current rating per port (A) 2; (adjustable: 0...2; Factory setting: 2) Sensor supply US Max. current load total (A) 3.6 Current rating per port (A) 2; (adjustable: 0...2; Factory setting: 0,45) Inputs/outputs Total number of inputs and outputs 16; (configurable) Number of inputs and outputs Number of digital inputs: 12; Number of digital outputs: 12 Inputs Number of digital inputs 12; (IO-Link Port Class A: 4 x 2; IO-Link Port Class B: 4 x 1) Switching level high (V) 11...30 Switching level low (V) 0...5 Digital inputs protected against short circuits yes Outputs Number of digital outputs 12; (IO-Link Port Class A: 4 x 1; IO-Link Port Class B: 4 x 2) Short-circuit proof yes Actuator supply UA Max. current load per output (mA) 2000 Sensor supply US Max. current load per output (mA) 2000 Interfaces Communication interface Ethernet ; IO-Link Ethernet Transmission standard 10Base-T; 100Base-TX Transmission rate 10; 100 Protocol PROFINET EtherNet/IP Factory settings IP address: 0.0.0.0 IP address: 192.168.1.250 subnet mask: 0.0.0.0 subnet mask: 255.255.255.0 gateway IP address: 0.0.0.0 MAC address: see type label Note on interfaces CC-C (Conformance Class C); S2-Redundancy; Configuration in Run (CiR); IRT Capability; SNMP Supported network topologies; line; ring; DLR IO-Link Master Transmission type COM 1/COM 2/COM 3 IO-Link revision 1,1 Number of ports class A 4 Number of ports class B 4 Operating conditions Ambient temperature °F (°C) -13...140 (-25...60) Storage temperature °F (°C) -13...+185 (-25 ... +85) Max. relative air humidity (%) 90 Protection IP 65; IP 66; IP 67 Degree of soiling 2

Articles in this issue

Archives of this issue

view archives of Datasheets - NC_Series_IOLink_Masters_Datasheet