Norgren Collateral

PGS Gripper Double Blank Sensor Kit User Instructions

Issue link: https://onenorgren.uberflip.com/i/1340293

Contents of this Issue

Navigation

Page 0 of 3

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. © 2020 Norgren Automation Solutions, LLC 10/20 00550UI REV: 002 160272.01 PGS Gripper Double Blank Sensors User In ruction Double Blank Sensor Kit Double Blank Sensor Kit Micro Catalog # Pico Catalog # Description SGS40040-K SGS40040P4-K NPN SGS40041-K SGS40041P4-K PNP Note: Whenever any part of the gripper is replaced including pads the sensor will need to be calibrated again. 1. NPN/PNP Sensor Technical Data: 2. User Interface: Micro Sensor Connector: 4 - Pin One Key (male) Micro Type Connector Pico Sensor Connector: 4 - Pin (male) Pico Type Connector Supply Voltage Range: 10 - 30 VDC Maximum Continuous load current: 100mA (max) Operating Temperature Range: 0°C to +60°C Response Time: 50ms max Indicator Light: Red Short Circuit Protection: Yes Overload Protection: Current limits at 325mA Typ. Reverse Polarity Protection: Up to 36 volts DC Interface: 3 - wire device Sensor Housing: Zinc Housing Seal: IP68

Articles in this issue

Archives of this issue

view archives of Norgren Collateral - PGS Gripper Double Blank Sensor Kit User Instructions