Page 6 of 10

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. © 2020 Norgren Automation Solutions, LLC Page 07 08/20 User In ructions for PGS10 and PGS11 Grippers 2. If an Indirect Sensor is to be installed, move brass bushing in sensor to align with drive pin in gripper. This must be done to correctly install sensor. Align dowel pins with slots of frame. Once pins are fully into slots, rotate sensor down onto frame. As rotation begins make sure bushing and drive pin are still aligned. Note: Whenever any part of the gripper is replaced including pads the sensor will need to be recalibrated, see Step J. 3. Clean and apply Loctite 262 or equivalent to M5 X 12mm SHCS for side plate or M5 X 16mm SHCS for sensor. Insert through side plate/sensor and into frame. Tighten M5 SHCS to 72in-lb. 1. Unlock jaws on gripper & open jaws to get access to pads. Side plates/sensor DO NOT need to be removed. Refer to Gripper Unlock Section B. 2. Remove M5X8mm SHCS from jaw. 3. Side Plate Indirect Sensor F. Installing a Side Plate or Indirect Sensor (cont.) G. Pad Replacement