Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document. © 2020 Norgren Automation Solutions, LLC Page 08 08/20
User In ructions for
PGS10 and PGS11 Grippers
3. Apply Loctite 262 to M5 X 8mm SHCS and insert into one of the jaws. Take replacement
pads and insert it into the opposite side of the jaw with SHCS sticking out. Thread SHCS
into pad and tighten to 72in-lb. Repeat step for other jaw. Chisel jaws only require one pad
Sensor must be calibrated whenever any part of the gripper is replaced including pads.
1. Part Present
a. To program the sensor for a particular material thickness, apply air to the gripper and
grip on the material thickness which is to be used for the particular job. With an object
such as a small Allen wrench, press the button until the Red LED corresponding to the
material range of the job lights as shown on the label.
b) Verify calibration:
(1) Close the gripper with no material between the pads. The LED should be off.
(2) Close the gripper on a single blank of material. The Red LED corresponding to your
material range should be on.
2. Double Blank
a) To program the sensor for a particular material thickness, apply air to the gripper and
grip on the material thickness which is to be used for the particular job. With an object
such as a small Allen wrench, press the button until the Red LED(s) corresponding to
the material range of the job lights as shown on the label.
H. Calibrating In-Direct
Sensor