Norgren Collateral

15698SP Tool Changers Catalog

Issue link: https://onenorgren.uberflip.com/i/867446

Contents of this Issue

Navigation

Page 16 of 39

*Air and electrics on the Easy Load receiver can be set to side exit (as shown above) or rear exit. 2 17 E A S Y L O A D www.imi-precision.com/autoinplant NASInsideSales@imi-precision.com 1-800-272-4511 EASY LOAD RECEIVER EZR3XXXXXXXXXXXX Mechanical Code Customer Specified Air Fittings* Check Valves Customer Specifies Electrical Pin Layout Customer Specified Electrical Connector* 6.54 (166.1) 2.92 (74.2) 1.77 (45) 1.77 (45) 2.02 (51.3) 4.80 (121.8) Dimensions inches (mm) Rule # If Statement Then Statement or Example 1 Top is reserved for hook only and the hook is mandatory 2 If handle is on the left Then left is not an option for electric, air, and code modules 3 If handle is on the right Then right is not an option for electric, air, and code modules 4 If handle is on the bottom Then bottom is not an option for electric, air, and code modules 5 Code, if none is not selected for number of pins Then none is not an option for location 6 Code, if none is selected for number of pins Then none is the only option for location 7 Electrics, if none is not selected for # of pins Then none is not an option for cable style, connector location, location on module 8 Electrics, if none is selected for # of pins Then none must be selected for cable style, connector location, location on module 9 Air, if none is not selected for number of air ports Then none is not an option for thread type, location on the module, location of module 10 Air, if none is selected for number of air ports Then none must be selected for thread type, location on the module, location of module 11 If handle is on the right And if electrics is right exit And if electrics is on left side of receiver And if air is selected And if air is side exit Then air can't be mounted on the bottom 12 If handle is on the left And if electrics is right exit And if electrics is on the bottom of receiver And if air is selected And if air is side exit Then air can't be mounted on the right 13 Not more than 3 modules can be mounted on a single side for example, you can have 2 air blocks and code, but not 2 air blocks and 2 electric blocks all on the left side Part number rules Note: Dimensions in inches (mm) are for reference only

Articles in this issue

Links on this page

Archives of this issue

view archives of Norgren Collateral - 15698SP Tool Changers Catalog