Life Science

z8507BR - Cadent Pump brochure

Issue link: https://onenorgren.uberflip.com/i/861563

Contents of this Issue

Navigation

Page 2 of 5

. Need to perform more complex commands? Our scripting tab breaks it down for you. See real-time status of pump movements with exact position confirmation. Send specific move commands with a few simple clicks. Need to use a different valve or syringe? You can easily update and home to the pump. Seamlessly connect and control multiple pumps. 1.00 10.00 20.00 30.00 40.00 50.00 60.00 Time (secs) Flow Rate (µL/min) 1.4 1.2 1 0.8 0.6 0.4 0.2 0 3 Cadent™ 3 Syringe Pump Outstanding Fluidic Performance Smarter, More Advanced Control As fluidic pioneers, we've taken the Cadent 3's design to the next level with superior technology that allows for faster bench testing, smarter serviceability, and easier integration. > Programmable troubleshooting via smart diagnostics > Built-in event and error logs > Query pump for status and error feedback > Instant status alerts through LED lights > Concealed reset/home button > Interactive graphic user interface for easy benchtop testing > Consolidated connections for flexibility of use across various instrument interfaces > Boosted encoder for optimum valve alignment, which decreases port occlusions and delivers: > Minimal flow turbulence > Assured dispense volume > Whisper-quiet operation (< 55dBA) The Cadent 3 syringe pump provides the reliability and control you need to have confidence in precise and accurate analysis: > Industry-leading low-flow stability down to 1μL/min with a 1mL syringe > Extended speed range: 1/16th half- steps/sec to 10,000 half-steps/sec > Premier accuracy: 0.2% full-stroke; 0.3% 1/10th stroke > Excellent precision: 0.05% Cv full- stroke; 0.5% Cv 1/10th stroke > Sustained performance on precision and accuracy over pump lifetime > Adjustable flow rate range: 0.008μL/ min to 500mL/min (based on syringe size, speed, and resolution 3 Cadent™ 3 Syringe Pump Flow variance over time [µl/min] Unique Low-Flow Stability With advanced microstepping capabilities and mechanical resolutions of up to 24,000, only the Cadent 3 syringe pump can smoothly capture information down to 1μL/min (using a 1mL syringe) to deliver the best performance in: > Complex imaging instruments: urinalysis and hematology > Laser applications: flow cytometry and particle counting > Additional low-flow needs for increased surface-area-to-volume sample delivery: mass spectrometry and nanoLC Cadent Connect: Interactive Graphic User Interface Flow rate measurements taken over a 60-second period on a 10KHz sample rate showing flow accuracy/stability of ±1%.

Articles in this issue

Archives of this issue

view archives of Life Science - z8507BR - Cadent Pump brochure