1/2 PTF (G1/2)*
1.18 (30) A/F
5.67
(144)
3.46
(88)
1/4 PTF (R
c
1/4)**
3.31 (84)
2.91
(74)
1.46
(37)
8.35
(212)
6.14
(156)
1/2 PTF (G1/2)*
1.18 (30) A/F
3.31 (84)
2.91
(74)
1.46
(37)
4.57
(116)
6.38
(162)
2.60 (66)
0.95
(24)
1.89
(48)
1/4
P72F
P74F
*Exhaust port
**Pilot port
• Controlled increase of downstream
pressure on start up reduces
possible damage and hazard
to personnel and equipment
• High forward flow capacity
• High flow dump facility
1.77
(45)
3.58
(91)
2.60 (66)
0.95
(24
)
1.89
(48)
M5**
1/4
Fluid:
Compressed air
Maximum pressure solenoid
operated:
150 psig (10 bar)]
Maximum pressure pilot operated:
250 psig (17 bar)
Minimum operating pressure:
44 psig (3 bar)
Operating temperature solenoid
operated:
0° to 125°F* (-20° to 50°C)
Operating temperature pilot operated:
0°* to 150°F (-20°* to 65°C) (72)
0°* to 175°F (-20°* to 80°C) (74)
* Air supply must be dry enough to avoid ice formation
at temperatures below 35°F (2°C).
P72F Series
24 VDC Solenoid
operated
P72F Series
Air pilot
operated
Port
size
PTF
Quickmount pipe
adapter
Quikclamp Quikclamp and
bracket
Connector Silencer
P72F-2AC-PFA P72F-2AA-NNN 1/4" 4215-02 4214-51 4214-52 54934-01 MB002A
P72F-3AC-PFA P72F-3AA-NNN 3/8" 4215-03 4214-51 4214-52 54934-01 MB002A
P74F Series
24 VDC Solenoid
operated
P74F Series
Air pilot
operated
Port
size
PTF
Quickmount pipe
adapter
Quikclamp Quikclamp and
bracket
Connector Silencer
P74F-4AC-PFA P74F-4AA-NNN 1/2" 4315-03 4314-51 4314-52 54934-01 MB004A
P74F-6AC-PFA P74F-6AA-NNN 3/4" 4315-04 4314-51 4314-52 54934-01 MB004A
Models
Accessories
Technical Data
In stock
Ships within one week
EXCELON MODULAR SYSTEM SOFT START/DUMP VALVE
P72F, P74F – 1/4" PTF TO 3/4" PTF
Dimensions - Inches (mm)
1
AM-134
For further information visit www.imi-precision.com and use the new
improved search function. If you cannot see the option you require please contact us.
AIR
MANAGEMENT
Online
at
www.imi-precision.com/us