4
AIR
PREPARATION
PRODUCTS
APP-92
For further information www.norgren.com
Ordering information
Models listed include relieving diaphragm and PTF threads. Requires a pilot regulator (ordered separately).
ISO Symbols Port Size Model Flow† scfm (dm3/s) Weight lb (kg)
1-1/2" R18-B00-RNXA†† 2000 (944) 6.82 (3.09)
2" R18-C00-RNXA†† 2000 (944) 6.61 (2.99)
† Typical flow with 100 psig (0.7 bar) inlet pressure, 90 psig (6.3 bar) set pressure and a droop of 15 psig (1 bar) from set.
†† Do not use the R41 feedback pilot regulator to control outlet pressures at or less than 100 psig (7 bar). Use the 11-104 feedback pilot regulator at those pressures.
Fluid:
Compressed air
Inlet pressure range:
10 psig (0.7 bar) minimum to
450 psig (31 bar) maximum
Operating temperature:
0° to 175°F (-18° to 80°C)*
* Air supply must be dry enough to
avoid ice formation at temperatures
below 35°F (2°C).
Materials
Body, bonnet, bottom plug, valve:
aluminum
Elastomers: nitrile
Technical data
Pilot Operated Regulators
R18
GrSym,Reg,ConvPilot
R18 with Conventional
Pilot Regulator
GrSym,Reg,FdbkPilot
R18 with Feedback
Pilot Regulator
Designed for systems that require pressure
regulation at an inaccessible location.
A pilot regulator (ordered separately) controls the
outlet pressure of the pilot operated regulator.
Alternative Models -R18
Port Size Substitute
1-1/2" B
2" C
Diaphragm Substitute
Relieving R
Non relieving (do not use with a
feedback pilot regulator)
N
Threads Substitute
PTF A*
ISO G parallel G
Gauge Substitute
Without N
With G
R 1 8 -H 0 0 -HH XH
* A factory installed gauge is only available with PTF threads (A in the last position of model number).