AIR
PREPARATION
PRODUCTS
4
APP-81
For further information www.norgren.com
11-018 Precision Air Pressure Regulator
1/4" Port Size
Panel mounting hole diameter: 0.47" (12 mm)
Maximum panel thickness: 0.094" (2.4 mm)
4.55
(116)
2.52
(64)
0.56
(14)
2.12 (54)
2.12
(54)
54 (2.12)
Typical Performance Characteristics
0 1.0 2.0 3.0 4.0 5.0 dm
3
/s
0 2 4 6 8 10 scfm
AIR FLOW
OUTLET
PRESSURE
psig
59
60
30
29
10
9
5
4
bar
0.70
0.65
0.60
0.35
0.30
2.10
2.05
2.00
4.15
4.10
LOW PRESSURE MODELS - FLOW CHARACTERISTICS
INLET PRESSURE: 100 psig (7 bar)
RANGE: 1 to 60 psig (0.1 to 4.1 bar)
0 2 4 6 8 10 bar
INLET PRESSURE
0 20 40 60 80 100 120 140 160 psig
OUTLET
PRESSURE
psig
59
60
30
29
10
9
5
4
bar
0.70
0.65
0.60
0.35
0.30
2.10
2.05
2.00
4.15
4.10
LOW PRESSURE MODELS - REGULATION CHARACTERISTICS
INLET PRESSURE: 150 psig (10.3 bar)
RANGE: 1 to 60 psig (0.1 to 4.1 bar)
OUTLET
PRESSURE
0 2 4 6 8 10 12 bar
INLET PRESSURE
0 20 40 60 80 100 120 140 160 180 psig
90
88
60
58
30
28
148
150
psig
bar
4.2
4.1
4.0
2.1
2.0
6.2
6.1
10.4
10.3
HIGH PRESSURE MODELS - REGULATION CHARACTERISTICS
INLET PRESSURE: 200 psig (14 bar)
RANGE: 3 to 150 psig (0.2 to 10.3 bar)
0 1.0 2.0 3.0 4.0 5.0 dm
3
/s
AIR FLOW
0 2 4 6 8 10 scfm
OUTLET
PRESSURE
psig
148
150
90
88
60
58
30
28
bar
4.2
4.1
4.0
2.1
2.0
6.2
6.1
10.35
10.30
10.20
HIGH PRESSURE MODELS - FLOW CHARACTERISTICS
INLET PRESSURE: 200 psig (14 bar)
RANGE: 3 to 150 psig (0.2 to 10.35 bar)
Dimensions in inches (mm)