AIR
PREPARATION
PRODUCTS
4
APP-33
For further information www.norgren.com
F64B/L F68V/Y
Olympian Plus plug in system
Adsorbing type activated carbon element removes
oil vapors and most hydrocarbon odors
Long service life of filter element. Minimum life of 400 hours
when the required oil removal filter is installed upstream and
the filtration temperature is between 70° to 80°F (20° to 26°C).
F68 V/Y inlet air must be prefiltered with an F68G and F68 C/H
Ordering information
Models listed are with PTF threads, and metal bowl.
*Maximum flow at 90 psig (6.3 bar) inlet pressure to maintain stated oil removal performance.
ISO Symbols Port size Model Maximum Flow* scfm ( dm3/s) Weight lb (kg)
1⁄4" F64B 15.0 (7.0) 4.07 (1.83)
1⁄2" F64L 23.3 (11.0) 5.56 (2.50)
3⁄4 " F64L 23.3 (11.0) 6.40 (2.88)
Standard flow (short element) F68V 53 (25) 5.13 (2.33)
High flow (long element) F68Y 127 (60) 5.70 (2.59)
Fluid:
Compressed air, neutral gases
NOTE: Contact technical support
for use with other media.
Maximum pressure
250 psig (17 bar)
Operating temperature*:
0° to +150°F (-20° to +65°C)
* Air supply must be dry enough to
avoid ice formation at temperatures
below +35°F (+2°C).
Maximum remaining oil
content:
0.01 mg/m
3
at +70°F (+20°C)
with an inlet concentration of
17 mg/m
3
.
Materials
Body: F64- zinc, F68-aluminum
Yoke: F64- zinc, F68-aluminum
Bowl: F64- zinc, F68- aluminum
Elastomers: nitrile
Service Kits:
F64 B/L 4380-201
F68V/Y 4380-302
Technical data
Olympian Plus Oil Vapor Removal Filter
F64C/H, F68V/Y
Auto Drain
Manual Drain