ACTUATORS 1 ACT-205 For further information www.norgren.com *Switch P/N Max Voltage Drop Enclosure Classification Temperature Rating Lead Wire Length Plug-In Cable Wiring Diagrams Hard Wired CS8-2-04 3.5 Volts NEMA 6 & CSA Approved -22 F to + 176 F 9 Feet N/A CS8-2-04P 3.5 Volts NEMA 6 & CSA Approved -22 F to + 176 F 8 mm Plug-in CS8-PIC-2 (2m) CS8-PIC-5 (5m) CS8-2-31 .5 Volts NEMA 6 & CSA Approved -22 F to + 176 F 9 Feet N/A CS8-2-31P .5 Volts NEMA 6 & CSA Approved -22 F to + 176 F 8mm plug-in CS8-PIC-2 (2m) CS8-PIC-5 (5m) CS8-2-32 .5 Volts NEMA 6 & CSA Approved -22 F to + 176 F 9 Feet N/A CS8-2-32P .5 Volts NEMA 6 & CSA Approved -22 F to + 176 F 8mm plug-in CS8-PIC-2 (2m) CS8-PIC-5 (5m) CS7-04 3 Volts NEMA 6 & CSA Approved -22 F to + 176 F 9 Feet N/A CS7-04-12P 3 Volts NEMA 6 & CSA Approved -22 F to + 176 F 12 mm plug-in CS7-PIC-5 (5m) CS7-PIC-10 (10m) CS7-9-04 3 Volts NEMA 6 & CSA Approved -22 F to + 176 F 9 Feet N/A CS7-10-04 3 Volts NEMA 6 & CSA Approved -22 F to + 176 F 9 Feet N/A CS7-31 .5 Volts NEMA 6 & CSA Approved -22 F to + 176 F 9 Feet N/A CS7-31P .5 Volts NEMA 6 & CSA Approved -22 F to + 176 F 12mm plug-in CS7-PIC-5 (5m) CS7-PIC-10 (10m) CS7-9-31 .5 Volts NEMA 6 & CSA Approved -22 F to + 176 F 9 Feet N/A CS7-32 .5 Volts NEMA 6 & CSA Approved -22 F to + 176 F 9 Feet N/A CS7-32P .5 Volts NEMA 6 & CSA Approved -22 F to + 176 F 12mm plug-in CS7-PIC-5 (5m) CS7-PIC-10 (10m) CS7-9-32 .5 Volts NEMA 6 & CSA Approved -22 F to + 176 F 9 Feet N/A CS7-24 N/A NEMA 6 & CSA Approved -22 F to + 176 F 9 Feet N/A CS7-9-24 N/A NEMA 6 & CSA Approved -22 F to + 176 F 9 Feet N/A CS9-04 N/A NEMA 1,4, and 13 (General Location) -4 F to +176 F 9 Feet N/A 1.66 .68 1.27 .327 1.40 .85 1.28 .86 Indicator light Hook up cable .68 CS7 Series Load Supply 120V Max _ + BRN 0.45 Center of Sensing area WHT Load Supply 6-24 VDC _ + BRN 0.10 Center of Sensing area WHT GRN GRN BRN WHT _ + Load Supply 6-24 VDC 0.10 Center of Sensing Area Supply AC/DC Load RED BLK + _ Load BLK RED Supply 6-24 VDC WHT + _ BLK RED WHT Load Supply AC/DC _ + AC supply BLK Load WHT RED SWITCH BLK RED GRN HOT NEUTRAL GROUND Both direct and alternating current Earth (ground) TERMINAL – ~ + – ~ - Magnetically operated switches (cont) CS8-2-* and CS7-* Switches (tie rod mounting bracket included)

Articles in this issue

Links on this page

Archives of this issue

view archives of Pneumatic & Fluid Control Catalog - z7424CT - 14 - Magnetically Operated Switches