ACTUATORS
1
ACT-119
For further information www.norgren.com
Guide blocks with roller bearings
QA/8000/61/*
Ø 32 ... 100 mm
***
**
*
**
f
Maximum load capacity is dependent on the
out stroke of a horizontally installed guide
unit. In the case of short stroke operation,
the load capacity figures taken from the
diagram must be multiplied by the correction
factor (diagram 2). In the curves of load
capacity (diagram 1), the short stroke
corrections have already been taken into
account for an outstroke > 60 mm.
The total deflection of guide rods will be
determined by the addition of that due to
own weight (diagram 3) and that due to load
capacity (diagram 4).
In the case of shock load applications, the figures given in the diagrams above must be reduced by a factor of 2.
Outstroke (mm)
** Outstroke
*** Center of gravity
* Center of gravity of load capacity
** Outstroke
Stroke (mm) Outstroke (mm) Outstroke (mm)
( N )
500
400
300
200
100
0
0 100 200 300 400 500 600
8080-8100
8050-8063
8040
8032
0 100 200 300 400 500 600
f
2,5
2,0
1,5
1,0
0,5
0
8032
8040
8050 - 8063
8080 - 8100
1,0
0,9
0,8
0,7
0,6
0,5
0 20 40 60
0 100 200 300 400 500 600
f
2,5
2,0
1,5
1,0
0,5
0
8032
8040
8050 - 8063
8080 - 8100
Maximum load capacity
depending on outstroke
Deflection caused by own
weight
Deflection caused by
a load of 10 N
(diagram 1) (diagram 2) (diagram 3) (diagram 4)
Load capacity Correction factor Deflection (mm) Deflection (mm)