5
FITTINGS
For further information www.norgren.com
FIT-56
ECM575A.Symbol with annotations
based on Symbol 24 Section 00
1 11
2
ECM575A.Drawing 1
K
ØF G
D E
J
I
H
B
C
A
Allows two independent signal sources to be
connected to a common pilot line
Can be used to perform an 'OR' logic function
Selects the highest of two applied pressures
Can be combined to operate from three or more
sources
Valves can be ganged together
Product Number Port Flow Factor Weight
NPT ISO G Size Cv oz. (kg)
T65A1800 T65C1800 1/8 0.42 1.9 (.055)
T65A2800 T65C2800 1/4 0.64 4.6 (.130)
NPT according to ANSI B1.20.1
Model A B C D E F G H I J K
T65A1800 1/8 NPT 0.30 0.59 0.79 0.3 0.21 0.39 0.24 0.39 1.00 1.42
T65C1800 G1/8 0.30 0.59 0.79 0.3 0.21 0.39 0.24 0.39 1.00 1.42
T65A2800 NPT1/4 0.39 0.79 0.98 0.49 0.21 0.49 0.31 0.47 1.18 2.00
T65C2800 G1/4 0.39 0.79 0.98 0.49 0.21 0.49 0.31 0.47 1.18 2.00
NPT according to ANSI B1.20.1
G according to BS 2779/ISO 228/1
T65 Series 1/8" and 1/4"
NPT and ISO G Shuttle Valves
Fluid:
Compressed air, filtered,
lubricated and non-lubricated,
inert gases
Operation:
Shuttle valve
Mounting:
Through holes in valve body
Port Size:
Female Thread
NPT
1⁄8 NPT T65A1800
1⁄4 NPT T65A2800
ISO G
G1⁄8 T65C1800
G1⁄4 T65C2800
Operating Pressure:
10 to 145 psi (0.7 - 10 bar)
Operating Temperature:
0° to 175°F (-20°* to +80°C)
*Consult our Technical Service for use
below 35°F
(2°C)
Materials
Body: Zinc
Ball: Nitrile
Seat: Brass
Technical data