FITTINGS
For further information www.norgren.com
5
FIT-53
Guidelines for typical installation
The air fuse should be installed directly between fixed or rigid pipework
and the flexible tube to protect the whole length of the flexible tube. Only
tubing after the air fuse is protected. The air fuse must be installed in the
correct orientation. Failure to do this will render it ineffective. When a shut
off valve is located before the air fuse, the valve must be opened slowly in
order to control initial air flow and avoid decompression effects which may
trip the air fuse.
It should be noted that the OSHA standard (29 CFR ChXVII Para
1926.302-b7) relating to pneumatic power tools states "All hoses
exceeding 1/2" inside diameter shall have a safety device at the source
of supply or branch line to reduce pressure in the case of hose failure."
**
**
**
**
**
**
*
*
*
*
*
*
Air
supply
Rigid line
Flexible line
T60
B
C
D
D
C
A
A/F
F
E
Model T60A289 T60C289 T60A389 T60C389 T60A489 T60C489 T60A689 T60C689 T60A889 T60C889 T60AB89 T60CB89
NPT ISO G NPT ISO G NPT ISO G NPT ISO G NPT ISO G NPT ISO G
A 0.81 0.81 0.94 0.94 1.25 1.25 1.25 1.25 2.00 2.00 2.50 2.50
B 2.01 2.01 2.44 2.44 3.07 3.07 3.54 3.54 4.65 4.65 5.71 5.71
C 1/4 1/4 3/8 3/8 1/2 1/2 3/4 3/4 1.0 1.0 1.5 1.5
D 0.39 0.43 0.41 0.55 0.59 0.54 0.56 0.75 0.66 1.00 0.68 1.00
E 0.12 0.12 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20
F 0.81 0.81 0.94 0.94 1.25 1.25 1.25 1.25 2.00 2.00 2.50 2.50
Air fuses
In-line excess flow shut-off valves
1/4 ... 1-1/2 NPT