Issue link: https://onenorgren.uberflip.com/i/555083
VALVES 2 VAL-479 For further information www.norgren.com 50 30 Ø58 177 149 59 36 12 43 20 47 PORT 'A' EXHAUST PORT 'C' INLET PORT 'B' OUTLET PORT 'D' OUTLET PORT 'E' EXHAUST VIEW ON TOP WITH TOP COVER REMOVED 47 29.5 www.thompson-valves.com Serial No. WARNING: DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT WARNING: MAXIMUM INTERNAL RISE 35K . USE SUITABLY RATED CABLE II 2 G D Ex d IIC T6 Ta Ex d IIC T4 Ta THOMPSON VALVES, ENGLAND, BH17 7EF. Model: ICO3S Ex tD A21 Maxseal Solenoid SIRA 05 ATEX 1156 IECEx SIR 05.0029 °C to °C to IP66/X8 V W °C Hz 90 °C 1180 + - CONDUIT CONNECTION SEE TABULATION 'C' 'A' 'E' 'D' 'B' Voltage (nominal) 24V DC Pull-in Voltage >= 87.5% of nominal Response Times (Typ) Pull-in < 80 MS Drop Out < 60 MS Drop-Out Voltage 10 - 20% of nominal Voltage Protection Surge suppression diodes fitted as STD Coil Encapsulation Class H Leak Performance Bubble tight at -50 ºC. <30cc/m at -55 ºC. Coil Duty Cycle 100% 64 Ø58 Ø 19.60 19.50 1.60 1.50 SEE NAMUR DETAIL NAMUR DETAIL SCALE 5:1 177 51 149 59 36 12 47 1 HOLE 5.5 X 3.0 DEEP MIN 32 16 46 22 34 2 OFF 5.5 MOUNTING HOLES PORT 'D' OUTLET PORT 'B' OUTLET PORT 'A' EXHAUST PORT 'E' EXHAUST PORT 'C' INLET 3 VIEW ON TOP WITH TOP COVER REMOVED 47 29.5 www.thompson-valves.com Serial No. WARNING: DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT WARNING: MAXIMUM INTERNAL RISE 35K . USE SUITABLY RATED CABLE II 2 G D Ex d IIC T6 Ta Ex d IIC T4 Ta THOMPSON VALVES, ENGLAND, BH17 7EF. Model: ICO3S Ex tD A21 Maxseal Solenoid SIRA 05 ATEX 1156 IECEx SIR 05.0029 °C to °C to IP66/X8 V W °C Hz 90 °C 1180 + - CONDUIT CONNECTION SEE TABULATION 'C' 'A' 'E' 'D' 'B' Profile and dimensions mm ICO3S 1/4" 5/2 VALVE 12 BAR (174 PSI) 5/2 fixed port configuration Certification T6 (Tamb = -55°C to +50°C (-67°F to +122°F)) & T4 (Max ambient +90°C (+194°F)) or equipment must be used within 'T' class temp ranges shown. EX II 2 GD - gas and dust environments. Exd protection, gas group IIC. Atex certification SIRA 05ATEX1156, complies with ATEX directive 94/9/EC IECEx certification IECEx SIR 05.0029 Safety integrity level SIL 3 or SIL 4 (SIL 4 in a redundant configuration only) Protection IP66/X8, NEMA 4X Electrical information Technical features Max. inlet pressure: 0-12 bar (0-174 psi) Flow rates: C V = 0.6 USgpm for 1 psi Δp K V = 8.7 l/min for 1 bar (15 psi) Δp Temperature ratings: Media (min/max): -55°C/90°C (-67°F/194°F) Ambient: must be used within 'T' class temperature ranges shown Port size: 1/4" Conduit / Signal Conns: M20 x 1.5mm IS0 (F) Media: Customer to specify and confirm compatibility ICO3S 1/4" 5/2 12 BAR (174 PSI) AUTO Process connections: NPT Weight: 2.3 kg Operation: Automatic Coil Rating: 74 ohms Power Consumption: 7.8 watts Materials: Valve body & trim - 316L stainless steel O-Rings seats & seals - nitrile Paint finish - 316LSS coil housing - unpainted Ordering information: Quote: Y015AA1H1BS Options: None ICO3S 1/4"5/2 NAMUR 12 BAR (174 PSI) AUTO Process connections: Namur mount with 1/4 NPT Weight: 2.3 kg Operation: Automatic Coil Rating: 74 ohms Power Consumption: 7.8 watts Materials: Valve body & trim - 316L stainless steel O-Rings seats & seals - nitrile Paint finish - 316LSS coil housing - unpainted Ordering information: Quote: Y015ANAH1BS Options: Namur mount supplied with A4-70 mounting bolts and O-rings