2
VALVES
VAL-512
For further information www.norgren.com
L+
N-
Ø82
30
Maxseal Solenoid
Model: ICO 4 S IP 66
EEx d II C T6 Ta (-60°C to 48°C)
EEx d II C T4 Ta (-60°C to 90°C)
THOMPSON VALVES, ENGLAND, BH17
Serial No.
www.thompson-valves.com
V
II 2 G
SIRA
00ATEX1147
W Hz
1180
DO NOT OPEN WHEN A FLAMMABLE
ATMOSPHERE IS PRESENT
CONDUIT CONNECTION
SEE TABULATION
164
201
55 22
96
78.0
22.2
25.4
36.3
VIEW WITH TOP COVER REMOVED
PORT 'A'
INLET
PORT 'C'
EXHAUST
PORT 'B'
OUTLET
25.4
18.2
15.0
38.1
25.4
14.8
12.1
56.0
53.4
50.8
134.9
65.7
2 HOLES 8.5
25.4
19.1
185.7
36,5
21
20
10
58.5
'C'
'B'
'A'
L+
N-
Ø82
30
Maxseal Solenoid
Model: ICO 4 S IP 66
EEx d II C T6 Ta (-60°C to 48°C)
EEx d II C T4 Ta (-60°C to 90°C)
THOMPSON VALVES, ENGLAND, BH17
Serial No.
www.thompson-valves.com
V
II 2 G
SIRA
00ATEX1147
W Hz
1180
DO NOT OPEN WHEN A FLAMMABLE
ATMOSPHERE IS PRESENT
CONDUIT
CONNECTION
SEE
TABULATION
164
201
55 22
96
78.2
50.8
A/FLATS
22.2
25.3
36.3
VIEW WITH TOP COVER REMOVED
Z
Y
PORT 'A'
INLET
PORT 'C'
EXHAUST
PORT 'B'
OUTLET
25.4
18.2
20
36,5
21
10
58,5
'C'
'A'
'B'
Profile and dimensions mm
ICO4S
3/2 MANIFOLD MOUNT
414 BAR
ICO4S MANIFOLD MOUNT 3/2 LM0 414 BAR
(6005 PSI)
3/2 norm (414B hyd / 300B
gas (6004 psi hyd / 4351
psi gas)) 3/2 uni (300B
hyd/150B gas (4351 psi
hyd/2176 psi gas))
Port size:
5 mm drilled ports
Coil Rating: 38 ohms
Power Consumption:
15.1 watts
Operation:
Lever manual override
Ordering information:
Quote: Y193MKFJ1BS
Options: Manifold mount
ICO4S MANIFOLD MOUNT 3/2 LMR 414 BAR
(6005 PSI)
3/2 3-port / 2-way not
suitable for universal opn
Port size:
5 mm drilled ports
Coil Rating: 125 ohms
Power Consumption:
6 watts
Process connections:
5mm drilled ports-flg mtd
Operation:
Lever manual reset
Ordering information:
Quote: Y193LKFJ1BS
Options: Manifold mount