2
VALVES
VAL-504
For further information www.norgren.com
L+
N-
58
Maxseal Solenoid
Model: ICO 4 S IP 66
EEx d II C T6 Ta (-60°C to 48°C)
EEx d II C T4 Ta (-60°C to 90°C)
THOMPSON VALVES, ENGLAND, BH17
Serial No.
www.fcx-thompson-valves.com
V
X
FC
II 2 G
SIRA
00ATEX1147
W Hz
1180
DO NOT OPEN WHEN A FLAMMABLE
ATMOSPHERE IS PRESENT
36
80
Ø82
206
243
120
138
30
'Y'
'Y'
58
55
22
151
VIEW ON TOP WITH TOP
COVER REMOVED
'A' PORT
INLET
'C' PORT
EXHAUST
'B' PORT
OUTLET
CONDUIT CONNECTION
SEE TABULATION
'C'
'B'
'A'
'C'
'A'
'B'
L+
N-
59
Maxseal Solenoid
Model: ICO 4 S IP 66
EEx d II C T6 Ta (-60°C to 48°C)
EEx d II C T4 Ta (-60°C to 90°C)
THOMPSON VALVES, ENGLAND, BH17
Serial No.
www.fcx-thompson-valves.com
V
X
FC
II 2 G
SIRA
00ATEX1147
W Hz
1180
DO NOT OPEN WHEN A FLAMMABLE
ATMOSPHERE IS PRESENT
Ø82
228
265
142
159
30
55 22
60
76
58
VIEW ON TOP WITH TOP
COVER REMOVED
'A' PORT
INLET
'B' PORT
OUTLET
CONDUIT CONNECTION
SEE TABULATION
L+
N-
Maxseal Solenoid
Model: ICO 4 S IP 66
EEx d II C T6 Ta (-60°C to 48°C)
EEx d II C T4 Ta (-60°C to 90°C)
THOMPSON VALVES, ENGLAND, BH17
Serial No.
www.fcx-thompson-valves.com
V
X
FC
II 2 G
SIRA
00ATEX1147
W Hz
1180
DO NOT OPEN WHEN A FLAMMABLE
ATMOSPHERE IS PRESENT
20
58.5
22 55
Ø81.6
261
224
138
156
30
162
98
54
76
70 - A/FLATS
VIEW ON TOP WITH TOP
COVER REMOVED
'A' PORT
INLET
'C' PORT
EXHAUST
'B' PORT
OUTLET
CONDUIT
CONNECTION
SEE TABULATION
Profile and dimensions mm
'C'
'A'
'B'
ICO4S
1/2" 3/2 AUTO VALVE
ICO4S 1/2" 3/2 A-L-L
Flow rates:
C
V
= 4.2 USgpm for
1 psi Δp
K
V
= 46 l/min for 1 bar
(15 psi) Δp
Valve size:
1/2" balanced poppet valve
ICO4S 1/2" 3/2 PBMR
Flow rates:
C
V
= 4.2 USgpm for
1 psi Δp
K
V
= 46 l/min for 1 bar
(15 psi) Δp
Valve size:
1/2" balanced poppet valve
ICO4S 1/2" 3/2 JSMO
Flow rates:
C
V
= 4.2 USgpm for
1 psi Δp
K
V
= 46 l/min for 1 bar
(15 psi) Δp
Valve size:
1/2" balanced poppet valve