VALVES
2
VAL-449
For further information www.norgren.com
Series 96000/97300 Solenoid actuated NAMUR valve
3/2 or 5/2 with NAMUR interface
5/2
6 7
Conversion instructions
5/2 way function (original mode of supply
/2 way function
3/2
6 7
3/2 or 5/2 way function can be
achieved just by swapping enclo-
sed adaptor plates.
Make sure Marker and Arrow
match as shown on above
drawing. Original mode of supply:
5/2 function.
Circuit diagrams
Power Consumption
24 VDC (W) 230 VAC (VA)
Protection
class
Temperatures
ambient/fluid
Electrical
connection
Separate
coil code
Coil code
1.7
4.3
IP 65 (with connector) -40°F to 122°F
(-40°C to 50°C)
DIN EN 175301-803
Form B
0000000305002400
0000000305023050
305002400
305023050
1.6
3.5
IP 65 (with connector) -40°F to 122°F
(-40°C to 50°C
DIN EN 175301-803
Form A
0000000303602400
0000000303623050
0000000303602400
303623050
Standard voltages 24 VDC, 230 VAC. Other voltages on request.
Connector is not included in delivery; Required connectors 068003 form B or 0570275 form A
6
Arrow
7
Marker