Pneumatic & Fluid Control Catalog - z7424CT

10 - IMI Herion Valves

Issue link: https://onenorgren.uberflip.com/i/555080

Contents of this Issue

Navigation

Page 19 of 57

VALVES 2 VAL-433 For further information www.norgren.com 4 2 3 1 5 V-32spec-EM-F V-32spec-EMH-F V-32spec-EMR-F 4 2 3 1 5 4 2 3 1 5 2 4 1 5 3 2 4 1 5 3 2 4 1 5 3 V-52-EM-F V-52-EMH-F V-52-EMH-F V-32spec-EM-EM V-32spec-EMH-EMH V-32spec-EMR-EMR 4 2 3 1 5 4 2 3 1 5 4 2 3 1 5 2 4 1 5 3 2 4 1 5 3 1 5 3 2 4 V-52B-EM V-52B-EMH V-52B-EMR 4 2 3 1 5 V-32spec-EM-F V-32spec-EMH-F V-32spec-EMR-F 4 2 3 1 5 4 2 3 1 5 2 4 1 5 3 2 4 1 5 3 2 4 1 5 3 V-52-EM-F V-52-EMH-F V-52-EMH-F V-32spec-EM-EM V-32spec-EMH-EMH V-32spec-EMR-EMR 4 2 3 1 5 4 2 3 1 5 4 2 3 1 5 2 4 1 5 3 2 4 1 5 3 1 5 3 2 4 V-52B-EM V-52B-EMH V-52B-EMR Symbol Valve model *1) Port size 1, 3, (5) 2, 4 Actuation/ Return Operating pressure (bar) Flow *4) (l/min) Test certificate IEC 61508 *2) 9710505* G 1/4 Flange Solenoid/Spring 2.5 ... 8 1300 x 9710515* 1/4 NPT Flange Solenoid/Spring 2.5 ... 8 1300 x 9710595* G 1/2 Flange Solenoid/Spring 2.5 ... 8 2600 9710596* 1/2 NPT Flange Solenoid/Spring 2.5 ... 8 2600 9711505* G 1/4 Flange Solenoid/Solenoid 2.5 ... 8 1300 9711515* 1/4 NPT Flange Solenoid/Solenoid 2.5 ... 8 1300 Symbol Valve model *1) Port size 1, 3, (5) 2, 4 Actuation/ Return Operating pressure (bar) Flow *4) (l/min) Test certificate IEC 61508 *2) 9710705* G 1/4 Flange Solenoid/Spring 2.5 ... 8 1300 x 9710715* 1/4 NPT Flange Solenoid/Spring 2.5 ... 8 1300 x 9711705* G 1/4 Flange Solenoid/Solenoid 2.5 ... 8 1300 9711715* 1/4 NPT Flange Solenoid/Solenoid 2.5 ... 8 1300 Housing: Aluminum anodized, Pilot flange: SNBR -40...+65C *3) Housing: Stainless steel, Pilot flange: SNBR -40...+65C *3) 1/4 NPT Flange Solenoid/spring Aluminum 2.5… 8 1300 0.45 4 9710219 G 1/4 Flange Solenoid/solenoid Aluminum 2.5… *2) Since May 2008, Date code A8192 *3) For operation in plants according to IEC 61511/61508 -40 ... +40°C see test certificate (on request) *4) Flow characteristics conforms to ISO6358 [6 » 5 bar] Note for *4): Connecting pipe / Fitting: In order to ensure and a pressure collapse avoid the flow, the supply air cross section shouldwith 1/4: ≥ 8 mm; with 1/2: ≥≥ 10 mm. With smaller cross section the inlet (A1) should more largely, however at least equally large line at the port (A2; A1). *1 Order example: To order a series 97105 NAMUR valve, stainless steel, G ¼" port with a 24 Vdc, IP65, DIN Form A coil, Model Number: 9710705076302400. Valve model code 9710705 + Coil code 076302400 = Model Number: 9710705076302400. To order the valve only, replace the * after the Valve model code from the table with 9 zero's, i.e. 9710705000000000. Order example: To order a series 97105 NAMUR valve, aluminum, G ¼" port with a 24 Vdc, IP65, DIN Form A coil, Model Number: 9710505076302400. Valve model code 9710505 + Coil code 076302400 = Model Number: 9710505076302400. To order the valve only, replace the * after the Valve model code from the table with 9 zero's, i.e. 9710505000000000. 97105 NAMUR 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT, flanged with NAMUR interface

Articles in this issue

Links on this page

Archives of this issue

view archives of Pneumatic & Fluid Control Catalog - z7424CT - 10 - IMI Herion Valves