VALVES 2 VAL-427 For further information www.norgren.com 97105 Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT Nominal- resistance RN coil (Ω) Min. required switching current (mA) Resistance RW 60 Coil (Ω) Required voltage- at terminal Rw 60 (V) Protection Class *1) (ATEX-Categorie) IP-Protection*1) (class according to EN60529) Temperature Ambient/Medium (°C) Order Separately Coil code 200 33 240 8 II2G Ex ia IIC T6 Gb II2G Ex ia IIC T4 Gb II2D Ex iaD 21 T80°C Db II2D Ex iaD 21 T100°C Db IP 66 (with cable gland) -40 ... +60 -40 ... +80 -40 ... +60 -40 ... +80 0000000205000000 205000000 391 24 460 11 II2G Ex ia IIC T6 Gb II2G Ex ia IIC T4 Gb II2D Ex iaD 21 T80°C Db II2D Ex iaD 21 T100°C Db IP 66 (with cable gland) -40 ... +60 -40 ... +80 -40 ... +60 -40 ... +80 0000000205100000 205100000 736 17 880 15 II2G Ex ia IIC T6 Gb II2G Ex ia IIC T4 Gb II2D Ex iaD 21 T80°C Db II2D Ex iaD 21 T100°C Db IP 66 (with cable gland) -40 ... +60 -40 ... +80 -40 ... +60 -40 ... +80 0000000205200000 205200000 1220 13 1460 19 II2G Ex ia IIC T6 Gb II2G Ex ia IIC T4 Gb II2D Ex iaD 21 T80°C Db II2D Ex iaD 21 T100°C Db IP 66 (with cable gland) -40 ... +60 -40 ... +80 -40 ... +60 -40 ... +80 0000000205300000 205300000 Solenoid actuators for intrinsically-safe circuits IP-Protection class *1) (to EN 60529) T *1) Ex protection classes and temperature values are valid for all solenoid. When selecting an intrinsically safe power supply, the permissible maximum values according to the Certificate of Conformity should be taken into account. Ui = 45 V Ii = 500 mA according to Tab. A. 208x PTB 06 ATEX 2001U — — N/en 7.1.540 Connector 0570275000000000 0663303000000000 (with rectifier) Adaptor complete (Adaptor, inlet filter and seal ring) Silencer (plastic) *1) Silencer (stainless steel) *1) Exhaust guard *2) Filter cartridge Add-on manual override Add-on manual override (for start-up only) 0613487000000000 M/S2 (G1/4) 0014613000000000 (G 1/4) 0613422000000000 (1/4") 0681173000000000 (1/4") 0553886000000000 (without detent) 0613379000000000 (without detent) C/S2 (1/4 NPT) 0613678000000000 (1/4 NPT) 0613423000000000 (1/2") 0553887000000000 (with detent) M/S4 (G1/2) 0014813000000000 (G 1/2) C/S4 (1/2 NPT) 0613679000000000 (1/2 NPT) Cable gland Protection Ex e, Ex d (ATEX), Nickel plated brass/ stainless steel Model Thread Cable Ø Material Protection class (ATEX) 0588819000000000 M 20x1.5 5.0...8.0 mm Nickel plated brass II2GD Ex e 0588851000000000 M 20x1.5 10...14 mm Nickel plated brass II2GD Ex d 0588925000000000 1/2-14-NPT 7.5...11.9 mm Nickel plated brass II2GD Ex d 0589385000000000 M 20x1.5 9.0...13 mm Model Approvals 1.4571 (316 Ti) II2GD Ex e 0589395000000000 M 20x1.5 7.0...12 mm Model Approvals 1.4571 (316 Ti) II2GD Ex d 0589387000000000 M 20x1.5 10...14 mm Model Approvals 1.4571 (316 Ti) II2GD Ex d Accessories *1) For indoors use only *2) For outdoors use ~ 0,2 (bar) Model Approvals ATEX IECEx FM 205x PTB 07 ATEX 2019 X IECEx PTB 07.0017 — Approvals