VALVES 2 VAL-449 For further information www.norgren.com Series 96000/97300 Solenoid actuated NAMUR valve 3/2 or 5/2 with NAMUR interface 5/2 6 7 Conversion instructions 5/2 way function (original mode of supply /2 way function 3/2 6 7 3/2 or 5/2 way function can be achieved just by swapping enclo- sed adaptor plates. Make sure Marker and Arrow match as shown on above drawing. Original mode of supply: 5/2 function. Circuit diagrams Power Consumption 24 VDC (W) 230 VAC (VA) Protection class Temperatures ambient/fluid Electrical connection Separate coil code Coil code 1.7 4.3 IP 65 (with connector) -40°F to 122°F (-40°C to 50°C) DIN EN 175301-803 Form B 0000000305002400 0000000305023050 305002400 305023050 1.6 3.5 IP 65 (with connector) -40°F to 122°F (-40°C to 50°C DIN EN 175301-803 Form A 0000000303602400 0000000303623050 0000000303602400 303623050 Standard voltages 24 VDC, 230 VAC. Other voltages on request. Connector is not included in delivery; Required connectors 068003 form B or 0570275 form A 6 Arrow 7 Marker