2
VALVES
VAL-400
For further information www.norgren.com
NC: Normally closed
2
1
Symbol 1: 2/2 NC
2
1 3
Symbol 2: 3/2 NC
Electrical characteristics
Voltage range +/- 10 %, duty cycle 100 %
Protection class according to EN 60529: IP51 with connector
Electrical insulation: 1000V AC
Insulation class F [311°F (155 °C)]
Electrical connection: Molex
®
For lubricated and unlubricated compressed air, neutral liquids
or gases
Poppet valve, directly actuated with spring return
High cycle rate of up to 1800 cycles per minute
Long life - in excess of 100 million cycles*
* Hit & Hold valves:
2/2 types with 0.06 inch orifice: 25 million cycles
3/2 types with 0.04 inch or 0.05 inch orifice: 50 million cycles
Sub-base mounted
Description
Solenoid valve for air, and neutral
liquids or gases. Air should be
filtered to 40 µm or less.
Switching function: normally
closed
Response time: 10 - 15 ms
Flow direction: determined
Fluid temperature: 14°F up to
122°F (-10°C up to 50°C
Ambient temperature: 14°F up
to 122°F (-10°C up to 50°C
Mounting position: as required
Materials
Body: PPS
Seat seal: NBR
Internal parts: Stainless steel, PA
6/6
Technical data
Connection Orifice Cv-Value Part Operating Function Manual Hit & Voltage Power Symb/
inch G/min m
3
/h number pressure psi override Hold * consumption Drawing
2/2 Direct acting valves / standard models
Flange 0.03 0.05 0.016 11-211P601-H0+1341+AYR** 0 - 116 NC No No 24 VDC 1.2W 1 / 1
Flange 0.05 0.10 0.026 11-211P602-H0+1341+AYR**
0 - 58 NC No No 24 VDC 1.2W 1 / 1
Flange 0.06 0.13 0.035 11-211P603-H0+6311+AZU**
0 - 116 NC No Yes 24 VDC 4W / 0.4W 1 / 1
3/2 Direct acting valves / standard models
Flange 0.03 0.05 0.013
11-311PI01-H0+1141+AYR**
29 - 116 NC Push only No 24 VDC 1.2W 2 / 2
Flange 0.04 0.10 0.026
11-311PI011H0+6111+AZR
29 - 116 NC Push only Yes 24 VDC 3W / 0.3W 2 / 2
Flange 0.05 0.13 0.035
11-311PI013H0+6111+AZR
29 - 94 NC Push only Yes 24 VDC 3W / 0.3W 2 / 2
** PWM energy saving option
** Optional surge suppression diode
Picosol 10 mm
2/2 & 3/2-way valves