VALVES
2
VAL-395
For further information www.norgren.com
Dimensions in Inches
Further options (valves)
XXXXXXX.8176 Solenoid in protection class – zone 2/22
II 3 GD EEx nA II T4 T 275°F
XXXXXXX.8186 Solenoid in protection class – zone 1/21
II 2 GD EEx me II T4 T 284°F
Further options on request
* For orders please state voltage and frequency, e.g.: 8392400.8171.23050 for 230V 50Hz or 8392400.8171.02400 for 24 VDC
** Cv-value (US) ≈ kv-Value x 1.2
Technical data (valves)
Solenoid 8171 (standard voltages) Power consumption
Design according to DIN VDE 0580
Voltage range ±10 %
Duty cycle (ED) 100 %
Protection class according to EN 60529: IP65
Electrical connector according to DIN EN 175301-803
The solenoids are UL listed and CSA approved
Profil
±
0.04
6kt. 50
2.95 ± .008
ø2.22 + 0.02
0.83
±
0.02
2.9
±0.04
ø1.40 + 0.02
ø1.34 ± 0.01
0.94
2.44
±
0.02
DN 25
6kt. 65
Profil
±0.04
4.9 ± 0.01
ø3.8 + 0.02
ø 2.0 + 0.02
ø 1.9 ± 0.008
1.18
3.2
±
0.02
1.34 ±
0.02
5.08
±
0.04
DN 40
Part number*
Solenoid
or
Nominal diameter inches Operating pressure (psi)
min. max.
Cv-Value** Weight
kg
8392400.8171.XXXXX 0.98 5.8 116 29 0.47
8392600.8171.XXXXX 1.57 5.8 116 78 1.1
DC AC
50 Hz 60 Hz
24V 24V –
– 110V 120V
230V 220V
Solenoid DC AC
Inrush Hold
8171 12W
23VA 16VA/8W
Series 83920
2/2-way valves