2
VALVES
VAL-384
For further information www.norgren.com
a
P
A
b
a
b
This valve is tested and certified
as a component by NSF International
against NSF/ANSI Standard 42
for materials and structural
integrity requirements only
and
against NSF/ANSI Standard 61
for material requirements only.
Description (standard valve)
Solenoid valve for potable water
and other neutral fluids
Switching function: normally closed
Flow direction: determined
Fluid temperature:
41°F to max. 122°F
(5°C to max. 50°C)
Ambient temperature:
32°F to max. 122°F
(0°C to max. 50°C)
Operating pressure:
4.35 to 152 psi (0.3 to 10.5 bar)
Mounting position: as required,
preferably solenoid vertical on top
Material
Body: Polymer (PPO GF 30)
Seat seal: EPDM
Internal parts: Stainless steel, PVDF
For contaminated fluids the use of a
strainer upstream of the valve is recom-
mended.
Features
High flow rate
Damped operation
Functional compact design
Solenoid interchangeable without
tools (Click-on
®
)
International approvals
For neutral gases and liquids
Indirectly solenoid actuated
Diaphragm valves
Internal threads 1/2" NPT and 3/4" NPT
Click-on
®
Solenoid
interchangeable
without
tools
Technical data valves
Solenoid 9101 (standard voltages)
Power consumption
Design according to DIN VDE 0580
Voltage range +/-10%, duty cycle 100%
Protection class according to EN 60529: IP65
Electrical connector according to DIN EN 175301-803 (included)
The solenoids are UL listed and CSA approved
Connection
size
NPTpsi
Orifice
inch
Cv-Value** Part number*
Solenoid in DC or AC
pressure
psi
1/2 0.5 3.5 8408214.9101.XXXXX 14.35 - 152
3/4 0.8 5.8 8408314.9101.XXXXX 14.35 - 152
* For orders please state voltage and frequency, e.g.: 8407214. 9101.23050 for 230V 50Hz or
8407214.9152.02400 for 24 VDC
** With gases and liquids up to 1 inch
2
/s (cSt)
DC AC
50Hz 60Hz
24V 24V -
- 110V 120V
205V 230V 220V
Solenoid DC AC
Inrush Holding
9101 8W 15 VA 12VA/7W
Technical specifications
Series 84080
2/2-way valves Orifice 0.5 to 0.8