2
VALVES
VAL-376
For further information www.norgren.com
a
P
A
b
a
b
DC AC
50Hz 60Hz
24V 24V -
- 110V 120V
- 230V 220V
Solenoid DC AC
Inrush Holding
8171 12W - -
8171 - 23VA 16VA
* For orders please state voltage and frequency, e.g.: 8332400.8171.23050 for 230V 50Hz
and 8332400.8171.02400 for 24 VDC
Connection
size
G
Orifice
Inches
Cv-Value Weight
(lb)
Part number Operating pressure psi
TPE
00
1 1.0 25.3 2.23 83324XX.8171.XXXXX 5.8 - 116
1-1/2 1.5 67.9 6.86 83326XX.8171.XXXXX 5.8 - 116
Description (standard valve)
Switching function: normally closed
Flow direction: determined
Fluid temperature:
-40°F up to 185°F
(-40°C up to 85°C)
Ambient temperature:
-4°F up to 185°F
(-20°C up to max. 85°C)
Operating pressure: 5.8 to 116 bar
Mounting position: as required,
preferably with solenoid vertical
on top
Material
Body: Stainless steel
Seat seal: TPE
Internal parts: TPU
Features
High flow rate
All internal components captive
Functional compact design
Solenoid interchangeable without
tools
Integrated silencer
One-piece diaphragm for longer life
For neutral gasses
Indirectly solenoid actuated
Diaphragm valves
Internal thread G 1 and G 1 1/2
Technical data
Design according to DIN VDE 0580
Voltage range +/-10%, duty cycle 100%
Protection class according to EN 60529: IP65
Electrical connector according to DIN EN 175301-803 (included)
The solenoids are UL listed and CSA approved
Power consumption
Solenoid 8171 (standard voltages)
Technical specifications
Series 83320
2/2-way valves Orifice 1 and 1-1/2