2
VALVES
VAL-340
For further information www.norgren.com
a
P
A
b
a
b
Operating pressure psi
Connection
size
NPT
Orifice
inch
Valve length
inch
Cv-Value Weight
(lb)
Part number for DC voltage* NBR
00
FPM
230°F (110°C)
03
EPDM
230°F (110°C)
14
HNBR
230°F (110°C)
51
1/4 0.4 1.7 1.7 1.1 82570XX.8001.XXXXX 0 - 145 0 - 145 0 - 145 0 - 87
3/8 0.4 1.7 2.0 1.1 82571XX.8001.XXXXX 0 - 145 0 - 145 0 - 145 0 - 87
1/2 0.4 2.4 2.0 1.32 82572XX.8001.XXXXX 0 - 145 0 - 145 0 - 145 0 - 87
* For orders please state voltage and frequency, e.g.: 8257000.800
4.
23049 for 230V 40-60Hz (AC with rectifier plug only, included) or 8257000.800
1.
02400
for 24 VDC
DC AC
40-60Hz
24V 24V -
- 110V 120V
230V 220V
Solenoid DC AC
Inrush Holding
8001 12W - -
8004 - 13VA 13VA
Description (standard valve)
Solenoid valve for slightly
aggressive gases and liquids
Switching function: normally closed
Flow direction: determined
Fluid temperature:
14°F up to max. 194°F
(-10°C up to max. 90°C)
Ambient temperature:
14°F up to max. 122°F
(-10°C up to max. 50°C)
Operating pressure:
0 to 145 psi (0 to 10 bar)
Mounting position: as required,
preferably with solenoid vertical
on top
Material
Body: Stainless steel, PA 66
Seat seal: NBR
Internal parts: Stainless steel,
PVDF, Sandvik 1802
For contaminated fluids the use of
a strainer upstream of the valve is
recommended.
Features
Suitable for vacuum
Functional design
Compact solenoid with integrated
core tube
Valve operates without differential
pressure
For slightly aggressive gases and liquids
Solenoid actuated, with forced lifting
Diaphragm valves
Internal thread 1/4" NPT to 1/2" NPT
Technical data
Solenoid 8001 (sandard voltages)
Power consumption
Design according to DIN VDE 0580
Voltage range +/-10%, duty cycle 100%
Protection class according to EN 60529: IP65
Electrical connector according to DIN EN 175301-803 (included)
AC with rectifier plug only
Technical specifications
Series 82570
2/2-way valves Orifice 0.4