2
VALVES
VAL-338
For further information www.norgren.com
a
P
A
b
a
b
Description (standard valve)
Solenoid valve for air, water, oil and
other neutral fluids
Switching function: normally closed
Flow direction: determined
Fluid temperature: 14°F up to max.
194°F (-10°C up to
max. 90°C)
Ambient temperature: 14°F up to
max. 122°F (-10°C up to
max. 50°C)
Operating pressure: 0 to 145 psi
(0 to 10 bar)
Mounting position: as required,
preferably with solenoid vertical
on top
Material
Body: Brass, PA 66
Seat seal: NBR
Internal parts: Stainless steel, PVDF
For contaminated fluids the use of a
strainer upstream of the valve is recom-
mended.
Features
Suitable for vacuum
Functional design
Compact solenoid with integrated
core tube
Valve operates without differential
pressure
Operating pressure: 0 - 290 psi (0 -
20 bar) with alternating current and
NBR sealing
Technical data
For neutral gases and liquids
Solenoid actuated, with forced lifting
Diaphragm valves
Internal thread 1/4" NPT to 1/2" NPT
Operating pressure psi
Connection Orifice Valve length
size inch inch Cv-Value Weight
(lb)
Part number* NBR FPM EPDM HNBR
NPT 230°F (110°C) 230°F (110°C) 302°F (150°C)
00 03 14 51
1⁄4 0.4 1.7 1.7 1.1 82630XX.8001.XXXXX 0 - 145 0 - 145 0 - 145 0 - 87
3⁄8 0.4 1.7 2 1.1 82631XX.8001.XXXXX 0 - 145 0 - 145 0 - 145 0 - 87
1⁄2 0.4 2.4 2 1.32 82632XX.8001.XXXXX 0 - 145 0 - 145 0 - 145 0 - 87
* For orders please state voltage and frequency, e.g.: 8263000.8001.23050 for 230V 50Hz or 8263000.8001.02400 for 24 VDC
DC AC
50Hz 60Hz
24V 24V –
– 110V 120V
– 230V 220V
Design according to DIN VDE 0580
Voltage range +/-10%, duty cycle 100%
Protection class according to EN 60529: IP65
Electrical connector according to DIN EN 175301-803 (included)
Solenoid DC AC
Inrush Holding
8001 12W – –
8001 – 20VA 16VA
Power consumption Solenoid 8001 (standard voltages)
Series 82630
2/2-way valves Orifice 0.4